Options to reset panel to factory settings On the Simplicity Plus, the CPU card is now integrated on the display PCB, so is no longer user upgradable. With this latest version, the panel still offers the simplicity of the previous versions, but also allows user configurations to zones &...
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 2. Reporting new Devices found Devices Found 1 After the system has been installed, and the cabling checked and the addresses of each device set, connect the loop to the fire alarm panel and power up the system Press ENTER to (mains &...
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 4 CHANGING A ZONE BOUNDARY The Simplicity`s default zone allocation may not be suitable for every installation. The Zone boundaries can now be altered as follows:-...
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 5 CHANGING THE ALARM RESPONSE - SOUNDERS System Menu 1: Clock 4: Timing 2: Zones 5: Misc By Default, the Simplicity uses a common alarm configuration. IE any alarm sets off all 3: Alarms 6: Reset sounders.
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 6 CHANGING THE ALARM RESPONSE – I/O UNITS Because a system could have several I/O units, each reacting to different types of events the simplicity system adopts the following method for configuring I/O units:- 1.
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 8 ALARM VERIFICATION The Simplicity now includes an option to use alarm verification. It is intended for use in apartments, and similar buildings, where it is desirable that an alarm from one apartment (or area) would need to be confirmed before the whole system goes into alarm.
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 9 RESTORING THE PANELS DEFAULT SETTINGS Because the simplicity now allows several configuration changes, we have also included System Menu an option to reset the panel back to it`s default operation. From Configuration Menu 2,...
SIMPLICITY PLUS / SIMPLICITY MICRO – ADDITIONAL FEATURES. Software Version :PANEL-R6180 (Plus) R5780 (Micro) 10 VIEWING PANEL INFORMATION 10.1 Menu Structure To help locate the different features available, the menu structure of the simplicity panel is shown here. MENU LAYOUT...