Smart Connect Multi-loop Installation Manual

Fault Finding

See troubleshooting section in SMART Connect Multi-loop Operation Manual (Doc: GLT-261-7-11)

Appendix A: SPECIFICATIONS

Code
Description
Standard
Main Supply
Mains Voltage
Mains Frequency
Battery Secondary Supply
Battery Voltage
Battery Charge Current
Battery Charge Voltage
Battery Derating Factor
On-board Relay Outputs
Fire Relay (Termination PCB)
Fault Relay (Termination PCB)
Mains Fault Relay (Charger PCB)
Fault Relay (Charger PCB)
Power Supply Outputs
Output A (Auxiliary Power)
Output B (Auxiliary Power)
Output C (Control Panel Power)
Output D (Control Panel Power)
Display
LCD Display
LED Indicators
Button Controls
General Panel Information
Maximum Software Zones
Maximum Event Log
Software Programming
Enclosure
Dimensions H x W x D (mm)
Weight
Cable Entries
Module Capacity
Power Supply
Battery Capacity
Environmental
Operating Temperature
Relative Humidity
www.zetaalarmsystems.com
SMART Connect Multi-loop Fire Alarm Panel
EN 54-2
EN 54-4
120-240V AC
50-60 Hz
SMART6
2 x 12V SLA
1.1A
27.3V @ 25°C
(C,NO,NC) Contact rating: 125VAC @ 0.5A / 30VDC @ 1A
Normally Energised (C,NO,NC) Contact rating: 125VAC @ 0.5A / 30VDC @ 1A
Normally Energised (C,NO,NC) Contact rating: 125VAC @ 0.5A / 30VDC @ 1A
Normally Energised (C,NO,NC) Contact rating: 125VAC @ 0.5A / 30VDC @ 1A
SMART6
29V @ 1A
29V @ 1A
29V @7.5A
29V @7.5A
4.3" Resistive touch screen. 480 x 272 pixel resolution
Fire, Sounder Fault, Fault, Sounder Active, Power, Controls Active, General
Disablement, General Test, Sounder Disablement, Sounder Delay, Relay Delay,
System Fault, More Data
32 zone LED indication (Optional MMP6)
64 zone LED indication (Optional MMP10/26)
Stop Sounders, Silence Buzzer, Silence Buzzer, Scroll Display, Reset, Start Sounders
(All other controls via touchscreen)
254 Zones
8032 Events
Via touchscreen or Windows 'Smart Configurator' software
SMART6
H: 535mm x W: 385mm x D:
150mm
8.5 kg
Top 18
Sides 12
Base 4
6
15A
14Ah max
-5°C (23°F) to 40°C (104°F)
93% Non-condensing
SMART10
SMART26
2 x 12V SLA
2 x 12V SLA
2.2A
2.2A
27.3V @ 25°C
27.3V @ 25°C
SMART10
SMART26
29V @ 1A
29V @ 1A
29V @ 1A
29V @ 1A
29V @7.5A
29V @7.5A
29V @7.5A
29V @7.5A
SMART10
SMART26
H: 665mm x W: 535mm
H: 665mm x W: 975mm x
x D: 200mm
D: 200mm
15 kg
Top 26
Sides 8
Base 4
10
15A
38Ah max
27 kg
Top 66
Sides 28
Base 20
26
15A
38Ah max
41

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMARTCONNECT SMART6 and is the answer not in the manual?

Questions and answers

Sanoop
April 18, 2025

How to identify double address detector

User image 6802a93cb31b4
1 comments:
Mr. Anderson
May 10, 2025

To identify a double address detector in the Zeta Alarm Systems SMARTCONNECT SMART6, check the DIP switch address settings. A double address detector will respond to two consecutive addresses. If two detectors are configured with the same DIP switch settings or respond to the same address, this indicates a double address condition. Use the DIP switch table to verify that each detector has a unique address.

This answer is automatically generated

Table of Contents

Save PDF