Operation
Calibration Instructions for Model 640M Indicator (lb, 8 weigh bar)
The following calibration instructions are for setting up an Avery Weigh-Tronix Model 640M for
weighing in Lb and an eight weigh bar Balzer Grain Cart. If this procedure doesn't get results within 1%
then field calibration must be performed.
1. From the Gross Mode, press and hold the HOLD/MENU
Key for three beeps, then release...
2. Use the Numeric Entry Procedure and enter in 640
3. Press the PRINT/SELECT key...
4. Press the PRINT/SELECT key...
5. Press the PRINT/SELECT key...
6. Use the Numeric Entry Procedure to enter the following
Configuration Code: 098390
7. Press the PRINT/SELECT key...
8. Press the MENU key once...
9. Press the PRINT/SELECT key...
10. Use the Numeric Entry Procedure to enter the following
custom code number: 074270
11. Press the PRINT/SELECT key...
12. Press the G/N key twice, busy is shown
Model 640M Calibration
50
SET.PAS is displayed
640 is displayed
640 is displayed
with all display annunicators lit
CONFIG is displayed
Current Configuration # is shown
098390 is shown
CONFIG is shown
CUSTOM is shown
Current Custom # is shown
074270 is shown
CUSTOM is shown
returns to Gross weighing mode