SENR9982
Table 20
Range
0 to 100 percent
Lower Position Limit
This is the minimum throttle percentage that will
be interpreted by the ECM as zero throttle. This
parameter is used with the value of initial lower
position limit to make an allowance for manufacturing
tolerances between different pedals.
Table 21
Range
0 to 100 percent
Upper Position Limit
This is the maximum throttle percentage that will be
interpreted by the ECM as full throttle. This parameter
is used with the value of the initial upper position limit
to make an allowance for manufacturing tolerances
between different pedals.
Table 22
Range
0 to 100 percent
Initial Lower Position Limit
This is the maximum throttle percentage that will
be interpreted by the ECM as zero throttle. This
parameter is used with the value of the lower
position limit to make an allowance for manufacturing
tolerances between different pedals.
Table 23
Range
0 to 100 percent
Initial Upper Position Limit
This is the minimum throttle percentage that will
be interpreted by the ECM as zero throttle. This
parameter is used with the value of the upper
position limit to make an allowance for manufacturing
tolerances between different pedals.
Table 24
Range
0 to 100 percent
Default
0 percent
Default
0 percent
Default
0 percent
Default
0 percent
Default
0 percent
Lower Dead Zone
This is a throttle range above the initial lower position
limit before the engine will increase in rpm.
Table 25
Range
0 to 100 percent
Upper Dead Zone
This is a throttle range that is below the initial upper
position limit that does not allow the engine speed
to increase.
Table 26
Range
0 to 100 percent

Multiposition Switch Setup

The multi-position throttle switch is an optional
throttle input. A maximum of four switches can be
used. Four switches will allow a maximum of 16
speeds to be selected.
When the multi-position switch is selected as the
"Throttle Type" on the "Throttle Configuration Screen"
of the electronic service tool, additional information
is required.
Number of Switch Inputs
This parameter is the total number of switches that
will be used. The switches may be individual switches
or a ganged rotary switch.
Table 27
Range
1 to 4
Physical Position
This parameter is non-programmable. The parameter
is used to signify the position of the rotary switch.
35