4. Hold the tool in position and gently pull the wire in
order to remove the terminal from the rear of the
connector (3).
5. Remove the removal tool from the face of the
connector (3).
Note: If a terminal must be replaced, part number
28170085 must be used.
Terminal Insertion
1. Push the terminal into the rear of the connector (3)
until the terminal engages with the locking device.
2. Gently pull on the wire in order to make sure that
the terminal is retained by the locking device.
3. Install the two terminal position assurance
components (2) into the sides of the connector (3).
4. Connect the connector to the ECM. Refer to
Disassembly and Assembly, "Electronic Control
Module - Remove and Install".
27