Perkins 1106D Troubleshooting Manual page 159

Industrial
Table of Contents

Advertisement

SENR9982
Illustration 56
Schematic for engine temperature sensors
Illustration 57
Engine coolant temperature sensor and intake manifold air
temperature sensor
(1) Signal (SIG)
(2) Ground (GND)
Test Step 1. Verify All Active Diagnostic
Codes.
A. Connect the Perkins Electronic Service Tool (EST)
to the data link connector.
B. Turn the keyswitch to the ON position.
Note: Wait at least 30 seconds for activation of the
diagnostic codes.
C. Use the Perkins EST in order to verify if any of the
following diagnostic codes are active or recently
logged:
110-03 Engine Coolant Temperature open/short
to +batt
110-04 Engine Coolant Temperature short to
ground
172-03 Intake Manifold Air Temperature
open/short to +batt
172-04 Intake Manifold Air Temperature short
to ground
Expected Result:
One or more of the preceding diagnostic codes are
active or recently logged.
Results:
Yes – Proceed to Test Step 2.
No – STOP.
g01170313
159
Troubleshooting Section
g01170933

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents