9.3 Menu overview

"Home"
Status
(factory settings)
Control mode
Operating status
Setpoint
Operating mode, from
Estimated flow
Control mode
Head
Pump performance
Max. curve and duty point
Resulting setpoint
Temperature
Speed
Operating hours
Power and energy consumption
Power consumption
Energy consumpt.
Warning and alarm
Actual warning or alarm
Warning log
Alarm log
Heat energy monitor
Heat power
Heat energy
Estimated flow
Volume
Hours counter
Temperature 1
Temperature 2
Differential temp.
Accuracy of values
Operating log
Operating hours
Trend data
Fitted modules
Date and time
Date
Time
Pump identification
Multipump system
Operating status
System performance
Power and energy consumption
Other pump, multipump system
"Settings"
Setpoint
Operating mode
Control mode
Controller settings (not model A)
Warning log 1 to 5
Alarm log 1 to 5
FLOWLIMIT
Automatic Night Setback
Analog Input
Estimated flow
Volume
Duty point over time
3D showing (Q, H, t)
3D showing (Q, T, t)
3D showing (Q, P, t)
3D showing (T, P, t)
Relay outputs
Operating mode, from
Control mode
Duty point
Resulting setpoint
System identification
Power consumption
Setpoint influence
Energy consumpt.
Operating mode, from
Speed
Operating hours
Pump identification
Power consumption
Normal
Stop
Min.
Max.
AUTOADAPT
FLOWADAPT
Prop. press.
Const. press.
Const. temp.
Diff. temp.
Constant curve
Controller gain Kp
Control. integr. action time Ti
Enable FLOWLIMIT function
Not active
Active
Set FLOWLIMIT
Not active
Active
Function of analog input
Not active
Differential-pressure control
Constant-temperature control
Differential-temperature control
Heat energy monitor
External setpoint influence
Unit
°C
°F
Sensor range, min. value
Sensor range, max. value
Electrical signal
0-10 V
4-20 A
Relay output 1
Not active
Ready
Alarm
Operation
Relay output 2
Not active
Ready
Alarm
Operation
External setpoint function
Not active
Linear with Min.
Temperature influence
Not active
Active, T
= 50 °C
max.
Active, T
= 80 °C
max.
"Assist"
Assisted pump setup
Setting of pump
Setting of date and time
Date format, date and time
Date only
Time only
Multipump setup
Setup, analog input
Description of control mode
AUTOADAPT
FLOWADAPT
Prop. press.
Const. press.
Const. temp.
Differential temp.
Constant curve
Assisted fault advice
Blocked pump
Pump communication fault
Internal fault
Internal sensor fault
Forced pumping
Undervoltage
Overvoltage
High motor temperature
External sensor fault
High liquid temperature
Comm. fault, twin-head pump
41