Sweep

Inputs

Note

IF INPUT

I Connector
Sensitivity
3-14 Specifications
Precision Type N female, front panel
100 Hz to 22 GHz, dc coupled
Continuous power: + 30 dBm from 5062 source.
Mixer protected by diode limiter, 100 Hz to 2.5 GHz.
Pulse power: 1100 W, 10 ~LS pulse width and 11% duty cycle with 150 dB input
attenuation (10 dBm peak power to input mixer).
0 to 70 dB in 10 dB steps
SMA female, front panel
-30 dBm at 321.4 MHz produces 0 dB
level 0 dBm, conversion loss set to 30 dB, resolution
bandwidth 1 MHz and a scale 1 dB/div.
+ 10 dBm continuous power from 5OQ source.
20 V with rise time of <l V/ps.
Sweep Time Accuracy
Sweep Time
Accuracy

Advertisement