Note
2-16 Installation
Figure 2-14. Slide Adapter for Non-HP System Rack Cabinets
b. Using hole pattern B, attach one adapter bracket to the rear of
each outer slide mount, using two M5x0.8~12 pan-head screws
and nuts per bracket.
c. Bolt an outer slide mount to each side of the system rack
cabinet using M5x0.8xl2 pan-head screws. Use the bar
nuts provided in the kit if the rack mounting strips have
through-holes.
If any binding is encountered in the slides after mounting, it will be
necessary to slightly move the adapter brackets. While supporting
the instrument, loosen one of the adapter brackets. Adjust the slides
slightly until they operate freely. Retighten the adapter brackets.
20. Connect the ac line power cords.
21. If the HP 8566B will be remotely controlled, refer to "To Set the
HP-IB Address" in this chapter.
22. When you turn your instrument on for the first time, you should
perform the verification tests in Chapter 5. Refer to the HP 8566B
Operating and Programming Manual for instructions on using
the instrument.