Tab.26
Menu
CIRCA
CIRCB
DHW
Tab.27
CLK parameter
HOURS
MINUTE
DATE
MONTH
YEAR
6.3
Setting the parameters
Fig.33
7613346 - v06 - 02072019
DHW menus
Description
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
Timer programming for domestic hot water
06:00 - 23:00 ON
23:00 - 06:00 OFF
Unit
Can be set from 0 to 23
Can be set from 0 to 59
Can be set from 1 to 31
Can be set from 1 to 12
Can be set from 2000 to 2100
6.3.1
1. Access the heating parameters by pressing the
2. Display the parameters for the required circuit by pressing the
MW-5000144-3
COUNTERS, TIME PROG, CLOCK
COUNTERS, TIME PROG, CLOCK
Setting the room temperature set point in comfort mode
Important
The room temperature set point can be managed via the TIME
PROG sub-menu dedicated to timer programming.
Important
To set the room set point temperature in reduced mode, it is
necessary to set the CP080 parameter available in the User
menu.
When the setting is made in a reduced mode range, this setting
shortcut is used only to set the set point temperature in comfort
mode corresponding to the CP081.
key.
\CIRCA, CIRCB and
\CLK menus
HMI
available
available
available
available
available
key twice.
200 ESL HYBRID
6 Settings
or
39