DeDietrich Alezio V220 Evolution User Manual

DeDietrich Alezio V220 Evolution User Manual

Reversible air / water heat pump "split inverter"

Advertisement

Quick Links

Export
en
User Guide
Reversible air / water heat pump "Split Inverter"
ALEZIO V220 EVOLUTION
AWHP-2 MIV-3 V220

Advertisement

Table of Contents
loading

Summary of Contents for DeDietrich Alezio V220 Evolution

  • Page 1 Export User Guide Reversible air / water heat pump "Split Inverter" ALEZIO V220 EVOLUTION AWHP-2 MIV-3 V220...
  • Page 2 Dear customer, Thank you for purchasing this appliance. Please read this manual carefully before using the product and keep it in a safe place for future reference. In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained. Our Service and After Sales organization can assist with this.
  • Page 3: Table Of Contents

    Contents Contents Safety ................... . 5 General safety instructions .
  • Page 4 Contents 10.2 Room thermostat and settings ..............28 11 Warranty .
  • Page 5: Safety

    1 Safety Safety General safety instructions Danger This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6: Liabilities

    1 Safety Note Remove the casing only to perform maintenance and repair work. Put the casing back in place after maintenance and repair work. Caution The appliance should be on Summer or Antifreeze mode rather than switched off to guarantee the following functions: Anti-blocking of pumps Frost Protection Note...
  • Page 7: About This Manual

    2 About this manual About this manual General This manual is intended for the end user of a AWHP-2 MIV-3 V220 heat pump. Symbols used 2.2.1 Symbols used in the manual This manual uses various danger levels to draw attention to special instructions.
  • Page 8: Technical Specifications

    3 Technical specifications Technical specifications Heat pump Maximum operating pressure: 3 bar Tab.1 Conditions of use Water (°C) Outside air (°C) Limit operating temperatures in Hot +18 / +60 AWHP 4 MR, AWHP 6 MR-2: -15 / +35 mode Other models: -20 / +35 Limit operating temperatures in Cooling +18 / +25 +7 / +40...
  • Page 9: Domestic Hot Water Tanks

    3 Technical specifications Tab.5 Common specifications Measurement Unit AWHP 4 AWHP 6 AWHP 8 AWHP 11 AWHP 11 AWHP 16 AWHP 16 type MR-2 MR-2 MR-2 TR-2 MR-2 TR-2 Total dynamic head at nominal flow rate Nominal air flow 2100 2100 3300 6000...
  • Page 10: Sensor Characteristics

    3 Technical specifications Tab.8 Weight Specification Unit Value Shipping weight Tab.9 Domestic hot water tank loading time AWHP/AWHP- AWHP 4 MR AWHP 6 MR-2 AWHP 8 MR-2 AWHP 11 MR-2 AWHP 16 MR-2 V220 AWHP 11 TR-2 AWHP 16 TR-2 4 hours 50 minutes 3 hours 15 minutes 2 hours 25 minutes 1 hours 40 minutes 1 hours 15 minutes Loading time (1) ΔT = 55K.
  • Page 11: Description Of The Product

    4 Description of the product Description of the product General description The ALEZIO V220 EVOLUTION heat pump is composed of: A reversible outside module for energy production in Hot or Cold mode. An inside module with a control panel to handle the thermal exchange between the R410A fluid and the hydraulic circuit.
  • Page 12: Control Panel Description

    4 Description of the product Control panel description 4.3.1 Description of the keys Fig.2 Control panel SERVICE " " " 1 Escape key 3 Domestic hot water temperature key or 2 Heating temperature key or [Enter] key 4.3.2 Description of the display Fig.3 Key functions Back to the previous level without saving the modifications made...
  • Page 13 4 Description of the product Fig.5 Operating indicators A manual vent cycle is running Permanent display of the Information menu The screed drying function is active SERVICE Shut-down/Frost Protection mode Compressor on Electrical or hydraulic back-up running Cooling mode on Domestic hot water mode active "...
  • Page 14: Operation

    5 Operation Operation Using the control panel The various menus can be accessed using various key combinations. Fig.7 Accessing the menus 1. Simultaneously press the C ( ) and D keys. The symbol flashes. SERVICE " " " Fig.8 Scrolling through the menus 2.
  • Page 15: Frost Protection

    5 Operation In the event of a prolonged absence (weekend, holiday), it is possible to switch to shutdown/frost protection mode. It is possible to produce domestic hot water all year round. User settings, page 17 Caution It is recommended that the heat pump never be completely shut down.
  • Page 16: Settings

    6 Settings Settings List of parameters 6.1.1 Choosing the hybrid operating mode Parameter Description Adjustment range Increment Factory setting Hybrid operating mode 0 to 2 0 = Deactivated 1 = Optimisation of primary energy consumption 2 = Optimisation according to energy cost (1) Only available if Note It is imperative that you input the energy cost parameters...
  • Page 17: User Settings

    6 Settings User settings Note If no keys are pressed, the settings menus are exited automatically after 10 seconds without saving the parameters. 6.2.1 Modifying the room temperature set point Fig.9 Press the B key. 1. Press the B ( ) key.
  • Page 18: Changing The Operating Mode

    6 Settings 6.2.3 Changing the operating mode 1. Press keys C ( ) and (D) simultaneously. The symbol flashes. 2. Confirm by pressing the D ( ) key. Fig.13 Modifying the value 3. Use the B ( ) or C key ( ) to modify the value.
  • Page 19: Reading Out Measured Values

    6 Settings Fig.16 Selecting the forcing desired 2. Hold the A key down and press the D key successively to choose the forcing desired. SERVICE Display Back-up Forcing the back-up for heating Forcing the back-up for domestic hot water " "...
  • Page 20 6 Settings Parameter Description Unit Estimated electrical energy consumption in cooling mode (1)(2) (1) Display available if the estimated electrical energy consumption function is activated (2) Cooling mode must be enabled. The estimated electricity consumption is displayed in 3 digits. The first digit indicates the scale (x1, x10, x100, x1000).
  • Page 21 6 Settings Display example Description Fig.21 Unit 1000 kWh The displayed value is 123000 kWh. The unit is 1000 kWh. The first digit indicates the scale x 1000. Only the first 3 digits are displayed. SERVICE " " " 7612035 - v02 - 12062014 AWHP-2 MIV-3 V220...
  • Page 22: Maintenance

    7 Maintenance Maintenance General instructions Maintenance operations are important for the following reasons: To guarantee optimum performance. To extend the life of the equipment. To provide an installation which offers the customer optimum comfort over time. Caution An annual service of the heat pump is mandatory. Maintenance instructions 1.
  • Page 23: Venting The Heating System

    7 Maintenance Note Filling and venting the installation twice a year should be sufficient to obtain an adequate hydraulic pressure. If it is often necessary to top up the installation with water, contact your installer. Venting the heating system It is essential that you vent any air in the domestic hot water tank, the pipes and the taps to prevent the annoying noises likely to be produced during heating or when drawing off water.
  • Page 24: Troubleshooting

    8 Troubleshooting Troubleshooting Error codes In the event of problems, the control panel displays the symbol and an error code. Caution Make a note of the code displayed. The error code is important for the correct and rapid diagnosis of the type of malfunction and for any technical assistance from your installer.
  • Page 25: Incidents And Solutions

    8 Troubleshooting Incidents and solutions Problems Probable causes Corrections The radiators are cold. The heating set point Increase the value of parameter or, if a room thermostat is temperature is too low. connected, increase the temperature on it. User settings, page 17. The heating mode is Activate the heating mode.
  • Page 26 8 Troubleshooting Problems Probable causes Corrections The water pressure is Not enough water in the Top up the installation with water. too low (< 1 bar). installation. Top up the installation with water, page 22. Water leak. Contact the installer. Clicking in the central The central heating pipe Contact the installer.
  • Page 27: Decommissioning Procedure

    9 Decommissioning procedure Decommissioning procedure Fig.28 Cutting the mains supply To decommission the heat pump temporarily or permanently: 1. Contact the installer. AD-0000155-A 7612035 - v02 - 12062014 AWHP-2 MIV-3 V220...
  • Page 28: Environmental

    10 Environmental 10 Environmental 10.1 Energy savings Tips on saving energy: Do not block ventilation outlets. Do not cover the radiators. Do not hang curtains in front of the radiators. Install reflective panels behind the radiators to prevent heat losses. Insulate the pipes in rooms that are not heated (cellars and lofts).
  • Page 29: Warranty

    11 Warranty 11 Warranty 11.1 General We would like to thank you for buying one of our appliances and for your trust in our product. In order to ensure continued safe and efficient operation we recommend that the product is regularly inspected and maintained. Your installer and our service department can assist with this.
  • Page 30: Appendix

    12 Appendix 12 Appendix 12.1 Declaration of Conformity Fig.29 Declaration of Conformity AWHP-2 MIV-3 V220 7612035 - v02 - 12062014...
  • Page 31 © Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.
  • Page 32 Бизнес-центр «Чайка Плаза», +49 (0)25 72 / 9161-102 офис 309 info@remeha.de +7 (495) 221-31-51 DE DIETRICH THERMIQUE Iberia S.L.U. DE DIETRICH SERVICE www.dedietrich-calefaccion.es www.dedietrich-heiztechnik.com Freecall 0800 / 201608 C/Salvador Espriu, 11 08908 L’HOSPITALET de LLOBREGAT +34 935 475 850 info@dedietrich-calefaccion.es DUEDI S.r.l.