Changing The Settings; Setting The Set Point Temperatures - DeDietrich AWHP MIT-IN iSystem User Manual

Air / water heat pump
Table of Contents

Advertisement

AWHP MIT-IN iSystem
4.3

Changing the settings

Menu C
Parameter
DAY TEMP. A
NIGHT TEMP. A
(1) (2)
ROOMTEM.COOL A
(2)
DAY TEMP. B
(2)
NIGHT TEMP. B
(2) (1)
ROOMTEM.COOL B
(2)
DAY TEMP. C
(2)
NIGHT TEMP. C
(2) (1)
ROOMTEM.COOL C
(2)
WATER TEMP.
(2)
TEMP.TANK AUX
(2)
DHW A TEMP.
(2)
TEMP.SOL.TANK
(2)
SWIMMING P.T.B
(2)
SWIMMING P.T.C
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
06/09/2012 - 300027618-001-01
4.3.1.
To set the various heating, DHW and swimming pool temperatures,
proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
MODE
C002266-A
Adjustment range Description
5 to 30 °C
Desired room temperature in comfort periods on circuit A
5 to 30 °C
Desired room temperature in reduced periods on circuit A
22 to 30 °C
Desired room temperature set point in cooling mode
5 to 30 °C
Desired room temperature in comfort periods on circuit B
5 to 30 °C
Desired room temperature in reduced periods on circuit B
22 to 30 °C
Desired room temperature set point in cooling mode
5 to 30 °C
Desired room temperature in comfort periods on circuit C
5 to 30 °C
Desired room temperature in reduced periods on circuit C
22 to 30 °C
Desired room temperature set point in cooling mode
10 to 65 °C
Desired domestic hot water temperature in the DHW circuit 55 °C
Desired domestic hot water temperature in the auxiliary
10 to 80 °C
circuit
10 to 80 °C
Desired domestic hot water temperature in circuit A
10 to 80 °C
Temperature of the hot water produced by solar power (TS) 55 °C
5 to 39 °C
Desired temperature for swimming pool B
5 to 39 °C
Desired temperature for swimming pool C

Setting the set point temperatures

To go back to the previous display, press the key j .
To cancel, press key h .
4. Operating the appliance
Factory setting
20 °C
16 °C
25 °C
20 °C
16 °C
25 °C
20 °C
16 °C
25 °C
55 °C
55 °C
20 °C
20 °C
16