6.4

Setting the parameters

Fig.34
Fig.35
MW-3000249-4
Fig.36
7682850 - v02 - 09012018
6.4.1
MW-5000144-3
6.4.2
MW-6000254-2
6.4.3

Setting the room temperature set point in comfort mode

Important
The room temperature set point can be managed via the TIME
PROG sub-menu dedicated to timer programming.
Important
To set the room temperature set point, it is necessary to set the
CP080 parameter available in the User menu.
When the setting is made in a reduced mode range, this setting
short cut is used only to set the temperature set point in the
comfort mode corresponding to CP081.
1. Access the heating parameters by pressing the
2. Display the parameters for the required circuit by pressing the
key.
3. Confirm by pressing the
The name of the circuit and the heating water temperature set
point are displayed alternately.
4. Access setting of the heating water temperature set point by press­
ing the
key.
5. Set the heating water temperature set point by pressing the
key.
6. Confirm the new temperature set point by pressing the
Important

Press the
key to cancel all inputs.

Setting the domestic hot water temperature

Important
Domestic hot water production can be managed via the TIME
PROG sub-menu dedicated to timer programming.
1. Access the domestic hot water production parameters by pressing
the
key.
2. Modify the domestic hot water temperature set point by pressing the
or
key.
Important

Press the
key to cancel all input.
3. Confirm the new temperature set point by pressing the
Go back to the main display by pressing the

Activating Forcing of the cooling function

Important
The cooling function can be managed via the PROG COOL sub-
menu dedicated to timer programming.
Important
The flow temperature set point for cooling mode corresponds to
the CP270 or CP280 parameters, depending on the type of circuit
configured (underfloor heating, convection fan). The CP270 or
CP280 parameters can be found in the Installer menu.
key twice.
key.

key.
MIV-4S
6 Settings
or
or
key.
key.
35