When the pressure adjusting dial is at "3" and the presser foot is lowered, the highest position
of the feed dog should be 0.75 to 0.85 mm from the surface of the needle plate.
w
q
e
r
!1
u
Adjusting Feed Dog Height
y
t
!2
i
o
!0
To adjust feed dog height
1. Remove the base cover, base lid (1) and bed
q
cover
.
2. Set the pressure dial at "3" and lower the
presser bar lifter, then turn the Power ON.
3. Turn the handwheel toward you until the feed
dog comes to its highest position.
4. Remove the Screw A
q
(Front)
.
5. Loosen the Screw B
6. Loosen the nut
height to 0.8 mm
y
screw C
.
7. Tighten the nut
8. Tighten the Screw B
To adjust the feed dog position parallel to
needle plate
Turn the handwheel toward you until the feed dog
u
comes to its highest position, the feed dog
and the needle plate should be parallel. If not,
follow the instructions below.
9. Prepare the hexagonal socket screw
insert it to the attaching hole (D)
it until the tip of screw reaches the bottom.
10. Loosen the screw E
hand screw.)
11. Turn the hexagonal socket screw (4 x 6)
and adjust the feed dog
needle plate.
12. Tighten Screw E
13. Loosen the hexagonal screw
it.
14. Reattach the bed cover (Front)
w
A
.
Reattach the bed cover, base cover and base
lid (1).
q
Bed Cover (Front)
w
Screw A
e
Screw B
r
Nut
t
0.75-0.85mm
y
Screw C
13
w
and the bed cover
e
.
r
and adjust the feed dog
t
by turning the adjusting
r
.
e
.
o
and screw
!1
( This screw is left
u
parallel to the
!0
.
i
and remove
q
with Screw
u
Feed Dog
i
Hexagonal Socket Screw (4x6)
o
Attaching Hole D
!0
Screw E (Left hand screw)
!1
Presser Foot
!2
Needle Plate Surface
u
i
and
i