Adjusting Remaining Bobbin Thread Sensor - Janome Memory Craft 10001 Servicing Manual

Hide thumbs Also See for Memory Craft 10001:
Table of Contents

Advertisement

Adjusting Remaining Bobbin Thread Sensor

Ver.
Main
Slave
Ver.
8 Adjust
Brightness
BH Sensor
SEW TEST
Foot Sensor
Bobbin
Foot UD
Test
Clear EEPROM
SET
Bobbin Thread
Key
MEM1
MEM2
OK
To adjust bobbin thread sensor:
1. Start up the machine in Adjusting Mode. Turn
the Power ON while pressing the Start/Stop
button and Reverse button at the same time.
(Keep pressing both buttons until the LCD
shows Adjusting window.)
2. Press the Bobbin key on the touch panel.
3. Insert the gauge bobbin (9.2 mm in diameter)
in the bobbin holder and press the key button.
(The numbers will appear under the key
button. Press the key button several times and
check if the same number appears each time.)
?
4. Press MEM1 button. (The data for step 3 is
registered in MEM1.)
5. Insert the gauge bobbin (10.3 mm in diameter)
in the bobbin holder and press the key button.
(The numbers will appear under the key
button. Press the key button several times and
check if the same number appears each time.)
6. Press MEM2 button. (The data for step 5 is
registered in MEM2.)
7. Make sure the difference of numbers for
MEM1 and MEM2 is 6 or more.
(The mean number of MEM1 and MEM2 will
be the standard data.)
8. Press OK button.
9. Turn the Power OFF.