6.2.1

Device Arrangement

Selecting a mounting location
In order to select the right mounting location, several factors must be considered:
• The scanning range determined from the scanning curve must be adhered to at all
locations at which a position determination is to be made
• The BPS should be mounted inclined 10° from vertical towards the barcode band to
ensure that the read results are reliably obtained even if the barcode band is soiled.
Notice!
The best functionality is obtained when:
• the BPS is guided parallel to the band
• the permitted working range is not exited
Notice!
On the BPS 37, the beam is not emitted perpendicular to the cover of the housing, but with
an angle of 10° towards the top. This angle is intended to prevent total reflection on the bar-
code band.