Installation
6.3.4
Wire Lengths and Shielding
The following maximum lengths for wires and the type of shielding to be used must be
observed:
Connecting
BPS 37 - Service
BPS 37/MA 4.7 -
Host
Switching input
Switching output
Table 6.2:
6.4
Disassembling, Packing, Disposing
Repacking
For later re-use, the device is to be packed so that it is protected against shocks and damp-
ness. Optimal protection is achieved when using the original packaging.
Notice!
Electrical scrap is a special waste product! Observe the locally applicable regulations re-
garding disposal of the product.
26
Interface
RS 232
SSI
Wire Lengths and Shielding
Max. wire length
10m
1200m
10m
10m
BPS 37
Leuze
electronic
Shielding
absolutely required, shield
meshing
absolutely required, flexible
leads as twisted pairs and
shielded
not necessary
not necessary
Leuze electronic