Service interface active
The service interface is activated via a bridge between the pins 7 and 15 on the 15-pin sub-
D connector. If the BPS 37 is operated with a connection unit, the service interface is acti-
vated through a switch in the connection unit.
Connection
You can connect a PC or terminal to the BPS 37 via the serial interface and configure the
BPS 37 through this connection. For this, you need a crossed RS 232 connection cable (null
modem cable) that provides the connections RxD, TxD and GND. The hardware handshake
at the service interface is via RTS. A CTS handshake is not supported.
If the BPS is connected to a connection unit, you can use the 9-pin sub-D service connector
in the connection unit. For the respective connection specifications please refer to the data
sheet of the connection unit.
Service Operating Mode
Figure 7.1: Connecting the service interface to a PC or terminal
8

Operation

8.1

Display Elements

On the BPS 37 there is an LED. It signals that the BPS is ready for operation.
Leuze electronic
PC
BPS 37
Service
15 GND
12 TxD
11 RxD
BPS
Operation
29