Manitowoc GROVE GMK 4100 Operating Instructions Manual page 11

Lattice extension
Table of Contents

Advertisement

10 m (33 ft) swing-
away lattice
Counter-
Telescoping
weight
Telescopic section
I-II-III-IV-V
in t
(lbs)
0.5 - 0 - 0- 0 - 0
6,3
(13 800)
0.5 - 0 - 0- 0 - 0
8,5
(18 700)
0 - 0 - 0- 0 - 0
0.5 - 0.5 - 0- 0 - 0
10,7
(23 500)
0 - 0 - 0- 0 - 0
0.5 - 0.5 - 0- 0 - 0
12,9
(28 400)
0 - 0 - 0- 0 - 0
0.5 - 0.5 - 0- 0 - 0
15,1
(33 200)
0 - 0 - 0- 0 - 0
0.5 - 0.5 - 0.5- 0 - 0
17,3
(38 100)
0 - 0 - 0- 0 - 0
Additional pages GMK 4100
All the axle loads in the following table are valid for a 20 t hook block
(weight: 300 kg (660 lbs)) reeved on the lattice extension.
Main
boom
angle
(°)
20 – 40
Not permitted!
20 – 30
78 – 80
20 – 40
78 – 80
20 – 35
75 – 80
5 – 25
75 – 80
20 – 30
75 – 80
3 112 331 en
Lattice
Main
exten-
boom
1)
sion incli-
position
nation
(°)
0 – 20
front
rear
0 – 20
front
0
rear
0 – 20
front
0 – 40
rear
0 – 20
front
0 – 40
rear
0
front
0 – 40
rear
0 – 20
front
0 – 40
rear
2)
Maximum axle load
in t
(x 1000 lbs)
front
rear
13,0
15,5
(28,6)
(34,2)
11,0
16,0
(24,2)
(35,4)
9,0
17,0
(19,9)
(37,5)
15,0
17,0
(33,1)
(37,5)
10,0
17,5
(22,0)
(38,6)
13,0
18,0
(28,6)
(39,7)
11,0
18,5
(24,2)
(40,8)
13,0
18,5
(28,6)
(40,8)
12,0
18,5
(26,4)
(40,8)
13,5
18,5
(29,7)
(40,8)
13,0
18,5
(28,6)
(40,8)
s
3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GROVE GMK 4100 and is the answer not in the manual?

This manual is also suitable for:

Grove gmk 4100-lGrove gmk 5095

Table of Contents

Save PDF