A.4

Notes on the use of expansion cards

Problem
Cause
The device
Redundant I/O addresses
crashes during
Redundant hardware interrupts
startup
and/or DMA channels
Signal frequencies or signal
levels are not adhered to
Different pin assignment
Insufficient output of an external
power supply, e.g., UPS
The device does
A counter voltage is fed into the
not start up or
device by connected or installed
switches off im-
expansion cards
mediately
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
A.4 Notes on the use of expansion cards
Remedy
Check your computer configuration:
If the computer configuration corresponds to the delivery
state, contact your technical support team.
In the case of a change in the configuration, restore the
delivery state. To do this, remove the expansion card and
restart the device. If the error no longer occurs, the expan-
sion card was the cause of the fault. Replace this with a
Siemens expansion card or contact the supplier of the ex-
pansion card.
If the device still crashes, contact your technical support team.
Use a powerful power supply.
Clarify the following with the supplier of the component:
The component can be operated without an external power
supply.
The component can be reconfigured so that it only uses the
external power supply or that of the device.
Technical support
175