Siemens SIMATIC Series Operating Instructions Manual page 150

Hide thumbs Also See for SIMATIC Series:
Table of Contents

Advertisement

Technical specifications
8.4 Technical specifications
Frequency
Transient voltage interruption
Power consumption with maximum
configuration and 230 W secondary
Power loss, heat emission
Current delivery (DC)
Noise emission
Pollution degree
Degree of protection
1
Dust protection
Safety
Protection class
1
Safety regulations
not evaluated by UL
1
150
Device with standard enclosure
50 to 60 Hz, min. 47 Hz to max. 63 Hz, sinusoidal
Power supply:
20 ms for 230 W
≤ 10 events/h; recovery time ≥ 1 s
Redundant power supply:
20 ms for 240 W
≤ 10 events/h; recovery time ≥ 1 s
Power supply ≤ 260 W with 90% efficiency
Redundant power supply ≤ 270 W with
85% efficiency
Power supply: 260 W = 260 J/s = 0.25 BTU/s
Redundant power supply: 270 W = 270
J/s = 0.26 BTU/s
Power supply:
+5 V/25 A, +3.3 V/20 A
190 W permitted in total
+12 V
/14 A, +12 V
/11 A
1
2
–12 V/0.1 A, +5 V
; 2 A
aux
Redundant power supply:
+5 V/20 A, +3.3 V/20 A
100 W permitted in total
+12 V1/16 A, +12 V2/16 A
–12 V/0.5 A, +5 Vaux; 3 A
The total sum of all voltages is max. 230 W.
< 45 dB (A) to DIN 45635
At 20 °C and in Windows idle mode the result is 40 dB (A).
Device is designed for environments with pollution degree 2
IP 30 (front) with closed front door
IP 20 on the rear according to EN 60529
With closed front door
Filter class G2 EN 779; particles > 0.5 mm are 99% retained
Protection class I compliant with IEC 61140
IEC 61010-2-201
EN 61010-2-201
UL 61010-2-201
CAN/CSA C22.2 No 61010-2-201
Device with short enclosure:
Operating Instructions, 04/2020, A5E49948632-AA
SIMATIC IPC547G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ipc547g

Table of Contents