7.3.8

Integrating a hot spare hard disk drive in the RAID system

If the hot spare hard disk drive was replaced in a RAID system, the new hot spare hard disk
drive must be integrated in the RAID system once again.
Requirement
A hot spare hard disk drive was replaced in the RAID system, see section "Replacing a
defective hard disk drive in the RAID system (Page 94)".
Procedure
1. Select "Start" > "Programs" > "Intel Rapid Storage Technology".
The RAID system is configured in the delivery state in such a way that a new hot-spare
drive is automatically integrated.
If the automatic integration of a hard disk in the RAID system is deactivated, the hard disk
must be integrated manually as described below.
2. Click
The new hard disk is found and displayed.
3. Use the right mouse button to mark the new hard disk and select the menu item "Mark
Disk as Spare" in the context menu.
4. Confirm the alarm in the "Mark Disk as Spare" window with "Yes".
7.4

Removing and installing hardware

7.4.1

Removing the device fan

7.4.1.1

Changing the front fan

Requirement
● The device is fully disconnected from the mains voltage; see section "Switching off the
device (Page 63)".
● The fan cover has been removed; see section "Remove the fan cover (Page 105)".
● A fan
Use only a fan of the same type.
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
"Run Hardware Scan now".
Device maintenance and repair
7.4 Removing and installing hardware