Electromagnetic compatibility
Emitted interference (AC)
Noise immunity:
interference conducted on the
power supply lines
Noise immunity on signal lines
Immunity to discharges of static
electricity
Immunity to RF interference
Magnetic field
Ambient conditions
Climatic ambient conditions
Temperature
Operation
Storage/transportation
Relative humidity
Operation
Storage/transportation
Atmospheric pressure
Operation
Storage/transportation
Mechanical ambient conditions
Vibration
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
EN 61000-6-3; EN 61000-6-4;
CISPR 22, EN 55022 Class B; FCC Class A /
EN 61000-3-2 class D, EN 61000-3-3
± 2 kV; according to IEC 61000-4-4; burst
± 1 kV; according to IEC 61000-4-5; surge symm
± 2 kV; according to IEC 61000-4-5; surge symm
± 2 kV; according to IEC 61000-4-4; burst; length > 30 m
± 1 kV; according to IEC 61000-4-4; burst; length < 30 m
± 2 kV; according to IEC 61000-4-5; burst; length > 30 m
± 4 kV contact discharge (according to IEC 61000-4-2)
± 8 kV air discharge; (according to IEC 61000-4-2)
10 V/m; 80 up to 1000 MHz
•
80% AM to IEC 61000-4-3
3 V/m; 1.4 to 2 GHz
•
80% AM to IEC 61000-4-3
1 V/m; 2 up to 2.7 GHz
•
80% AM to IEC 61000-4-3
10 V; 150 kHz up to 80 MHz
•
80% AM to IEC 61000-4-6
30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)
Tested according to IEC 60068-2-2; IEC 60068-2-1; IEC 60068-2-14
+0 °C up to +40 °C
1
Gradient: ≤ 10 K/h; no condensation
–20 °C up to +60 °C
Gradient: ≤ 20 K/h; no condensation
Tested according to IEC 60068-2-78; IEC 60068-2-30
0 to 31 °C: 5-85 %; decreasing linearly to 5-50 % at 40° C
5% up to 95% at 25 °C to 55 °C; no condensation
Gradient: ≤ 20 K/h; no condensation
1080 up to 689 hPa,
corresponds to an altitude of –1000 m to 3000 m
1080 up to 660 hPa,
Corresponds to an altitude of -1000 m to 3500 m
Tested according to IEC 60068-2-6; 10 cycles
Technical specifications
8.4 Technical specifications
151