FIGURE FUSE1
Fuse Jumper
One 1/4 x 1 1/4" Fuse Far Side
The main fuse(s) on the SNAP 700 are located inside the AC power entry
receptacle. The entry has a fuse drawer that holds the fuse(s) and selects the
appropriate line voltage. If the number in the window DOES NOT match the AC
line voltage intended to be supplied to the printer, DO NOT plug the power cord
in. Reconfigure as follows:
1) Remove the power cord.
2) Using a flat blade screwdriver, open the AC entry by lifting the tab just above
the voltage indicator window.
WARNING: Attempting to open the AC entry with
the AC power cord inserted into it will cause
damage to the AC entry.
3) Remove the red fuse drawer.
4) Remove all fuses and the fuse jumper if it is present.
5) Insert into the fuse drawer the correct number and style of fuses and fuse
jumper for your application.
Configuration Number One: Line voltage between the range of
1) Install one 921167 - 10.0A 250V Fast Acting 1/4 x 1 1/4"
2) Install one Fuse Jumper
See Figure FUSE1
Configuration Number Two: Line voltage between the range of
1) Install two 990757 - 6.3A 250V 5 x 20MM
NOTE: The fuse jumper must be removed to
install both 5 x 20mm fuses.
The fuses must be between points A and B as shown not B and C.
See Figure FUSE2
FRONT
Location of 115V Text
Location of 230V Text
6) Reinsert the fuse drawer into the AC entry with the desired voltage up.
7) Close the AC entry and verify the correct voltage is now visible.
90 - 132VAC @ 50 - 60Hz 1 Ph
180 - 265VAC @ 50 - 60Hz 1 Ph
FIGURE FUSE2
5 x 20 mm fuse
A
B
Two 5 x 20MM Fuses One Each Side
93
FRONT
Location of 115V Text
C
Location of 230V Text