Technical Data

Technical Considerations

PV modules paired with the C250 must have conductors labeled "PV Wire" or "PV Cable" to be compliant
with NEC 690.35(D) for Ungrounded PV Power Systems. Be sure to verify the voltage and current
specifications of your PV module match those of the microinverter.
WARNING: Risk of equipment damage. You must match the DC operating voltage range
of the PV module with the allowable input voltage range of the Enphase Microinverter.
WARNING: Risk of equipment damage. The maximum open circuit voltage of the PV
module must not exceed the specified maximum input voltage of the Enphase
Microinverter.
The output voltage and current of the PV module depends on the quantity, size and temperature of the
PV cells, as well as the insolation on each cell. The highest PV module output voltage occurs when the
temperature of the cells is the lowest and the PV module is at open circuit (not operating). The maximum
short circuit current rating of the PV module must be equal to or less than the maximum input DC short
circuit current rating of the microinverter.

Specifications

C250 Microinverter Specifications
Topic
Recommended input power (STC)
MPPT voltage range
Operating range
Maximum DC input voltage
Minimum / Maximum start voltage
Maximum DC input short circuit current
Rated (continuous) AC output power (-40C to +65C)
Peak AC output power
Output power factor
Nominal AC output voltage range
Maximum AC output current at nominal voltage
Nominal AC output frequency range
Maximum AC output over current protection device
Maximum AC output fault current & duration
Voltage trip limit accuracy of nominal
Frequency trip limit accuracy
Trip time accuracy
Maximum microinverters per 20 amp AC branch circuit
35
Enphase C250 Microinverter Parameters
DC Parameters
AC Parameters
Miscellaneous Parameters
 2015 Enphase Energy Inc. All rights reserved.
C250 System Installation and Operation
Unit
Min
W
V
27
V
16
V
V
22
A
W
W
Vrms
Amps
Hz
57
A
A/ms
590mA RMS for 6 cycles
2.5
%
Hz
±0.1
Cycles
±2
Typical
Max
350
48
60
60
60
15
240
253
>0.95
220 – 248
1.0
60
65
20
48
141-00025 Rev 03