10. Lift sump from dishwasher tank.
CAUTION: Tank edges are sharp! Use gloves, cover
tank edges and remove sump carefully.
5.15.2 Installing sump
To make sure the sump is seated properly onto the tank, the
following steps must be followed. The dishwasher must be right
side up during sump installation.
1. Install backflow valve.
2. Install aqua sensor.
3. Install water switch.
702_58300000170749_ara_en_c
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
4. Do not reconnect heat and drain pumps until later.
5. Place the base right side up.
6. Lay the sump loosely onto the base where it would be in
it's final position. In other words, lay the sump onto the
base right side up, centered under the tank cutout in a
position to be reconnected to the heat pump and hose.
7. Lift the dishwasher onto the base and reconnect the base
to the tank using the two (2) front and two (2) rear base
screws.
8. Using one hand, carefully lift the sump up to the tank. Use
the hand you won't be using to screw in sump screws.
9. Using your other hand, insert screws in the order shown
below, starting at the top left screw and going cw
(clockwise) around the sump to use the screws to raise the
sump to the tank.
10. Use a gauge to check the clearance of the sump to the
tank cutout. The clearance at all points around the sump
must be 1mm or less.