2. Remove hose clamp to separate pump from adapter
(below).
3. Disconnect support strap (below).
4. To remove pump, slide pump off sump at seal ring. The
seal ring can't be field removed from the heat pump.
702_58300000170749_ara_en_c
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
5. Disconnect the two (2) pump wire harnesses (below left).
To remove the small connector for the sensor harness with
black wires, unlatch it from it's terminal (below center).
6. If necessary, remove the adapter by removing four (4)
screws (below right).
TIP: The replacement heat pump comes with motor, pump,
seal ring and hose clamp.
NOTE: The motor can't be separated from the pump and
the seal ring can't be field installed.