Water Inlet Control - Bosch SHP65TL5UC Repair Instructions

Hide thumbs Also See for SHP65TL5UC:
Table of Contents

Advertisement

5.7.1
To remove aqua sensor
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers.
1. Remove parts for bottom front access – section 5.1.4.1.
2. If needed for access, remove power module – section
5.3.2.2
3. Lift up housing latch, twist aqua sensor counter-clockwise
(ccw) and pull aqua sensor out from sump.
5.7.2
To install aqua sensor
1. Insert aqua sensor into sump with pc board vertical, then
twist clockwise (cw).
TIP: Apply some rinse-aid onto the aqua sensor O-
ring to lubricate it for easier installation.
702_58300000170749_ara_en_c
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
5.8

Water inlet control

The water inlet control is easily accessed from the left side of the
dishwasher.
It includes a condensation vent, so there's no
separate condensation tube. The water inlet, sump and drain
hoses all connect to it.
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers.
1. Disconnect & pull out dishwasher – section 5.1.5.1.
2. Remove lower rack (below left).
needed, remove the upper rack as well.
3. Unscrew condensation vent cap ccw (counterclockwise)
from inside of tank (below right).
4. Loosen hose clamp (1) from water inlet hose (2) and pull
water inlet hose from water inlet (3, below).
5. Pull out drain (4) and sump (5) hoses from water inlet
control (below).
3
4
If more space is
1
2
5
Page 52 of 82

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents