5 T
1 L
T
O
IER
OSS
EST
PERATION
R
EFERENCING METHODS
Limit
= Length of fiber * Loss/km + L
14763-3
= 1 dB + Length of fiber * Loss/km (dB) + 0.75 dB + 0.75 dB +
Limit
= Length of fiber * Loss/km + L
TIA/11801
= 1.5 dB + Length of fiber * Loss/km (dB) + 0.75 dB + 0.75 dB +
38
One jumper reference method
The dual-ended reference removes the losses at connection 1
and connection 4 from the measurement.
One jumper reference for single-mode fiber
Fig. 11 One jumper reference: single-mode remote and single-mode
loopback
For more information on performing a measurement refer to
Fig.
18.
Reference connector to reference connector mated loss: 0.2 dB
Reference connector to random connector: ISO 14763-3: 0.5 dB,
TIA 568.3/ISO 11801: 0.75 dB
Random to random connector: 0.75 dB
Splice loss: 0.3 dB
L
+ L
(0.5 dB)
splice5
conn6
0.3 dB
L
+ L
(0.75 dB)
splice5
conn6
0.3 dB
(0.5 dB) + L
conn2
conn3
(0.75 dB) + L
conn2
conn3
+ L
conn4 +
+ L
conn4 +
OLTS-85

Advertisement

Table of Contents
loading

Table of Contents