– Cable Manufacturer
– Cable Name
– Connector: SM SC, SM LC, SM ST, MM SC, SM LC, SM ST
– Direction: unidirectional, or bidirectional
– Reference Method: 1 jumper, 2 jumper, or 3 jumper
– Limit: TIA 568.3, ISO 11801, ISO 14763-3
– Number of Connections: Specify the number of connections
in the fiber system under test. Don't count the reference
connections. They are already considered in the loss test cal-
culation.
– Loss per Connection (dB): 0.1 to 0.75
– Number of Splices
– Loss per Splice (dB): 0.1 to 0.3
– Length Limit (m)
– Cable Loss
To delete the test setup (reference method presettings):
The instrument is in Tier 1 Test mode.
1.
Press the [A] key.
2.
Tap the [Test
Setup]
3.
Tap the desired test setup.
4.
Press the [A] key.
5.
Tap the
[Delete]
button.
6.
Tap the
[OK]
button.
Performing a Tier 1 loss test
To perfom a Tier 1 loss test generally:
The Device Type of the instruments are set.
The cable properties are stored.
The Test Setup is set and selected (see "Referencing methods"
on page 37).
The local and remote instrument are in Tier 1 Test mode.
1.
Tap the [Set
Reference]
2.
Connect the reference cords according to the touchscreen
prompt.
3.
Connect your fiber under test.
4.
Tap the [Auto
Test]
5.
If necessary, change the cords and tap the
as prompted.
Pass/Fail, Margin, and Length are displayed.
button.
button to start the reference method.
button to start the loss test.
[Continue]
button