Cisco ONS 15454 ETSI Manual page 49

Table of Contents

Advertisement

Chapter 1 Install the Shelf and Common Control Cards
Table 1-2
AEP Cable Wire
Black
White
Slate
Violet
Blue
Green
Yellow
Orange
Red
Brown
Continue with the
Step 6
procedure on page
Stop. You have completed this procedure.
NTP-G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin
Connections
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Always use the supplied ESD wristband when working with a powered ONS 15454 ETSI. Plug the
Caution
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
78-17704-02
Pin Assignments for the AEP
Backplane Pin
AIC-I Signal
A1
GND
A2
AE_+5
A3
VBAT–
A4
VB+
A5
AE_CLK_P
A6
AE_CLK_N
A7
AE_DIN_P
A8
AE_DIN_N
A9
AE_DOUT_P
A10
AE_DOUT_N
"NTP-G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections"
1-49.
This procedure installs alarm, timing, LAN, and craft wires on the
ONS 15454 shelf. These wires are attached to the mechanical interface card
(MIC) FMECs on the ETSI shelf and are attached to the backplane on the
ANSI shelf.
Connectors according to function
Twisted #22 or #24 AWG (0.51 mm² or 0.64 mm²) shielded wires for LAN
or craft
75-ohm coaxial cable with 1.0/2.3 miniature coax connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) alarm wires
NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only), page
1-30
NTP-G5 Remove the Backplane Covers (ANSI Only), page 1-28
As needed
Onsite
None
NTP- G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections
AEP Signal
AEP_GND
AEP_+5
VBAT–
VB+
AE_CLK_P
AE_CLK_N
AE_DOUT_P
AE_DOUT_N
AE_DIN_P
AE_DIN_N
Cisco ONS 15454 DWDM Procedure Guide, R8.0
1-49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15454 ansi

Table of Contents