Loading And Updating Software Procedures - Frymaster FilterQuick easyTouch FQG60T Service Manual

Hide thumbs Also See for FilterQuick easyTouch FQG60T:
Table of Contents

Advertisement

1.24

Loading and Updating Software Procedures

Updating the software takes approximately 30 minutes. The software only needs to be loaded in the USB port in the far-left fryer
cabinet and it will update ALL the controllers and boards in the system. To update the software, follow these steps carefully:
The software update may lose the location of product icons on the front screen after the update. Take
either a picture/notation of the product locations on the 12 lanes for each vat to ensure they can be
loaded back at the end of the update.
Check with the manager about any LTO's (Limited Time Offer) products that may have been
programmed into the controllers. If so, capture the product details such as product name, cook time,
etc. to program in later.
MUST
The following reset
1.
Power cycle the fryer control power using the reset switch. This is located under the USB slot on the far-left side of the fryer
ENSURE THE SWITCH IS PRESSED AND HELD FOR 30 SECONDS
(see Figure 58).
2.
With the vats OFF, remove the jug of oil from under the fryer and manually top off the vats to the upper oil level line prior to
starting the update.
3.
Pull the filter pan slightly out of the fryer until "P" is visible in the top right corner of the displays.
4.
On the FAR-LEFT controller press the HOME button.
5.
Press the SERVICE button.
6.
Press the SERVICE button again.
7.
Enter 3000.
8.
Press the check button.
9.
Press the down arrow button.
10. Press the FIB-RESET 2 button.
11. Press YES to confirm.
12. RESET COMPLETED SUCCESSFULLY is displayed once the reset is complete. If a CAN
COMMUNICATION FAILED error occurs see Troubleshooting in section 1.25.1.
13. Press the check button.
14. Press the home button.
To update the software, follow these steps carefully:
Switch ALL controllers to OFF. Press the home button then the information (?) button;
1.
press the down arrow; press the SW version button. The controller displays INTIALIZING.
Write down the current (UIB, SIB, VIB and FIB) software versions.
On the FAR-LEFT controller press the HOME button.
2.
3.
Press the SERVICE button.
4.
Press the SERVICE button again.
5.
Enter 3000 for and press the checkmark button.
6.
Press the TECH MODES button.
7.
Press the down arrow.
8.
Press the SOFTWARE UPGRADE button.
9.
Controller displays INSERT USB.
10. Open the far-left cabinet door and slide the USB cover up (see Figure 56).
11. Insert the USB flash drive (see Figure 57).
12. The controller displays IS USB INSERTED? YES NO
13. Press the YES button after the USB flash drive is inserted.
14. Controller displays READING FILE FROM USB. PLEASE DO NOT REMOVE USB WHILE READING.
15. Controller displays READING COMPLETED, PLEASE REMOVE USB.
16. Remove the USB flash drive and lower cover over the USB slot.
17. Press the YES button after the USB flash drive is removed.
18. Controller displays CONFIRM CONTROLLERS AVAILABLE FOR UPGRADE UIB, SIB, VIB AND FIB or
SOFTWARE UPDATE WILL TAKE APPROXIMATELY 30 MINUTES. YOU WILL NOT BE ABLE TO COOK
DURING THIS TIME. CONTINUE WITH SOFTWARE UPDATES?
19. Press the YES button to continue.
20. Controller displays UIB/SIB/VIB/FIB – DATA TRANSFER IN PROGRESS, WILL COMPLETE IN X MINUTES for each board.
21. Controller displays UIB/SIB/VIB/FIB – UPGRADE IN PROGRESS, WILL COMPLETE IN X MINUTES for each board.
22. When the software update is complete, the controller will display UPGRADE COMPLETE? YES on the far LEFT controller.
23. Press the YES button.
24. The controller displays UPGRADE COMPLETED, POWER CYCLE THE SYSTEM.
be performed to clear items before updating.