22. "CLOSE DISPOSE VALVE" is displayed.
23. Close dispose valve.
24. "FILL VAT FROM BULK? is displayed.
25. Press "NO" if you wish to leave vat empty and exit.
1.21.4.3

Fill Vat from Bulk

1.
The vat must be off.
2.
Press the filtration menu button.
3.
Press the ADVANCED FILTER OPTIONS button.
4.
Select FILL VAT FROM BULK.
5.
"FILL VAT FROM BULK? is displayed.
6.
Press the √ (check) button.
7.
"START FILLING? PRESS AND HOLD" is displayed.
8.
Press and hold the button to fill the vat.
9.
"RELEASE BUTTON WHEN FULL" is displayed.
10. Release the button when the vat is full.
11. "CONTINUE FILLING?" is displayed
12. Press the √ (check) button to continue filling or press "NO" to exit.
1.21.4.4

Fill Oil Reservoir from Bulk *

1.
When TOP OFF OIL EMPTY is displayed, the oil reservoir (top-off container) is empty.
2.
To refill reservoir, press and hold the orange reset button above the reservoir until the reservoir is full.
3.
Release the button to stop filling.

1.21.5 Troubleshooting Oil Reservoir Filling

*NOTE: The reservoir may not fill if any of the following are in progress:
If FILTRATION REQUIRED – FILTER NOW? YES/NO, or SKIM, DEBRIS FROM VAT – PRESS CONFIRM WHEN
COMPLETE are displayed, the fill reservoir button is disabled until either a filter is complete or until NO is chosen.
The system also checks these conditions. The following must be met before an oil reservoir fill is allowed:
Solenoid closed
Orange fill button pressed longer than 3 sec.
FILTRATION REQUIRED – FILTER NOW? YES/NO, or SKIM, DEBRIS FROM VAT – PRESS CONFIRM WHEN
COMPLETE cannot be displayed
System power cycle (all boards – Controllers, SIB, VIB and FIB) after changing setup from JIB to Bulk (use
momentary reset). Ensure reset is pressed and held for at least sixty (60) seconds.
No filtration or other filter menu selection can be in process.
Other factors that may not allow fill reservoir from bulk –
Defective solenoid
Defective orange reset switch
Bulk oil pump issue
Bulk oil relay stuck
If using two fryer systems that are both attached to the bulk oil system, they may not be able to fill both units at
the same time if they have a bulk fresh oil unit with a single head. Some bulk oil fresh units have dual heads
which can fill simultaneously.