1.15

Loading and Updating Software Procedures

Updating the software takes approximately 30 minutes. The software only needs to be loaded in the USB port in the far-
left fryer cabinet and it will update all the controllers and boards in the system. To update the software, follow these
steps carefully:
1.
Switch all controllers to OFF. Press the information (?) button; press the down arrow; press the SW
version button. The controller displays INTIALIZING. Write down the current M4000 (UIB)/VIB/ FIB/SIB
software versions.
2.
On the far-LEFT controller press the HOME button.
3.
Press the SERVICE button.
4.
Press the SERVICE button again.
5.
Enter 1650 and press the checkmark button.
6.
Press the TECH MODES button.
7.
Press the down arrow.
8.
Press the SOFTWARE UPGRADE button.
9.
Controller displays INSERT USB.
10.
Open the far-left cabinet door and slide the USB cover up (see Figure 32).
11.
Insert the USB flash drive (see Figure 33).
12.
The controller displays IS USB INSERTED? YES NO
13.
Press the YES button after the USB flash drive is inserted.
14.
Controller displays READING FILE FROM USB. PLEASE DO NOT REMOVE USB WHILE READING.
15.
Controller displays READING COMPLETED, PLEASE REMOVE USB.
16.
Remove the USB flash drive and lower cover over the USB slot.
17.
Press the YES button after the USB flash drive is removed.
18.
Controller displays CONFIRM CONTROLLERS AVAILABLE FOR UPGRADE VIB,
SIB, FIB AND UIB.
19.
Press the YES button to continue or NO to exit.
20.
Controller displays UIB/VIB/SIB/FIB – DATA TRANSFER IN PROGRESS, WILL
COMPLETE IN X MINUTES for each board.
21.
Controller displays UIB/VIB/SIB/FIB – UPGRADE IN PROGRESS, WILL
COMPLETE IN X MINUTES for each board.
22.
When the software update is complete, the controller will display UPGRADE
COMPLETE? YES on the far LEFT controller.
23.
Press the YES button.
24.
The controller displays UPGRADE COMPLETED, POWER CYCLE THE SYSTEM.
25.
Cycle the fryer control power using the switch on the front of the left
contactor box (see Figure 34). ENSURE THE SWITCH IS TURNED OFF FOR 30
SECONDS.
26.
While the fryer is rebooting some controllers may take up to 10 minutes to
reboot as the software is loading.
27.
Once all controllers have returned to the power standby switch, go to the
next step.
28.
VERIFY software update by pressing the information (?) button; press the
down arrow; press the SW version button.
INTIALIZING. Ensure that the M4000(UIB)/VIB/FIB/SIB software versions have
updated.
29.
Press the home button.
30.
Press the CREW MODE button.
31.
The software update is complete.
The controller displays