1.2 FQ4000 Password Codes

Press the HOME button to enter MENUS, RECIPES, SETTINGS or SERVICE menus.
1650 – MENUS, RECIPES,
1656 – SETTINGS (MANAGER), SERVICE (MANAGER)
3000 – SETTINGS (SERVICE), SERVICE (SERVICE) Enter Tech Mode
9000 – Component Check [SETTINGS (SERVICE), SERVICE (SERVICE) Enter Tech Mode]
The following code is entered when prompted to do so.
1111 – Reset SERVICE REQUIRED Message – Enter when the issue is fixed and prompted to enter code.

1.3 Service Required Errors

A SERVICE REQUIRED error with a description of the error displays on the controller. After YES is pressed the alarm
is silenced. The controller displays an error message from the list below three times with the location of the error.
Then the controller displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen, enter code 1111. If NO is chosen, the
system returns to cook mode if possible, for 15 minutes, then redisplays error until issue is fixed.

1.4 Error Log Codes

To access the error log, press the home button. Press the service button. Press the manager button. Enter 1656
and press the check button. Press the E-log button. The ten most recent errors are listed from top to bottom, with
the top error being the most recent error. A "G" indicates a global error such as a filtration error.
errors in split vats are indicated by L for left or R for right. Pressing the left down arrow allows scrolling through the
errors. If no errors are present the screen will be blank
Code
E13
TEMPERATURE PROBE FAILURE
E16
HIGH LIMIT 1 EXCEEDED
E17
HIGH LIMIT 2 EXCEEDED
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
E19
HEATING FAILURE – XXX F or XXX C
E25
HEATING FAILURE - BLOWER
E27
HEATING FAILURE - PRESSURE SWITCH - CALL SERVICE
E28
HEATING FAILURE – XXX F or XXX C
E29
TOP OFF PROBE FAILURE - CALL SERVICE
E32
DRAIN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E34
RETURN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E35
RETURN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
E36
VALVE INTERFACE BOARD FAILURE - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E37
AUTOMATIC INTERMITTENT FILTRATION PROBE FAILURE
- FILTRATION DISABLED - CALL SERVICE
E39
CHANGE FILTER PAD
E41
OIL IN PAN ERROR
E42
CLOGGED DRAIN (Gas)
E43
OIL SENSOR FAILURE - CALL SERVICE
E44
RECOVERY FAULT
E45
RECOVERY FAULT – CALL SERVICE
ERROR MESSAGE
.
TEMP Probe reading out of range
High limit temperature is past more than 410°F (210°C), or in
CE countries, 395°F (202°C)
High limit switch has opened.
Vat temperature exceeds 460°F (238°C) and the high limit has
failed to open. Immediately disconnect power to the fryer
and call service.
Heating Control latch circuit failed.
Heat Contactor failed to latch.
The air pressure switch(s) failed to close.
The air pressure switch has failed closed.
The fryer has failed to ignite and has locked out the ignition
module.
ATO RTD reading out of range
Drain valve was trying to open and confirmation is missing
Drain valve was trying to close and confirmation is missing
Return valve was trying to open and confirmation is missing
Return valve was trying to close and confirmation is missing
Valve Interface Board connections lost or board failure.
AIF (VIB Probe) RTD reading out of range.
25-hour timer has expired, or dirty filter logic has activated.
The system detects that oil may be present in the filter pan.
Vat did not empty during filtration
Oil level sensor may have failed.
Recovery time exceeded maximum time limit.
Recovery time exceeded maximum time limit for two or more
Reset the error code by going to: HOME -> SERVICE
cycles.
-> SERVICE ->3000-> TECH MODE -> RESETS -> RECOVERY
FAULT CALL SERVICE -> YES.