Code
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL SERVICE
E51
DUPLICATE BOARD ID - CALL SERVICE
E52
USER INTERFACE CONTROLLER ERROR - CALL SERVICE
E53
CAN BUS ERROR - CALL SERVICE
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL SERVICE
E62
SLOW HEATING FAILURE XXXF OR XXXC - CHECK ENERGY
SOURCE - CALL SERVICE
E63
RATE OF RISE
E64
FILTRATION INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
E65
E65
E66
DRAIN VALVE OPEN – XXXF OR XXXC
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED - CALL
SERVICE
E68
FUSE TRIPPED – CALL SERVICE
E69
RECIPES NOT AVAILABLE
E70
OQS TEMP HIGH
E71
OQS TEMP LOW
E72
TPM RANGE LOW
E73
TPM RANGE HIGH
E74
OQS ERROR
E75
OQS AIR ERROR
E76
OQS ERROR
ERROR MESSAGE
SIB board 1 connection lost or board failure.
Two or more controllers have the same location ID.
The controller has an unknown error.
Communications are lost between boards.
SIB board 2 connection lost or board failure.
The vat is not heating properly.
Rate of rise error occurred during a recovery test.
Filtration Interface Board connections lost or board failure.
The float switch does not detect oil.
1. Ensure the frypot is full of oil.
2. Float switch may be stuck up or down.
3. Clean the float switch.
Ensure when removing the float switch that its position is
clearly marked and replaced properly. Installing the float
upside down will change the switch from N/O to N/C. This
could allow the empty frypot to ignite. Ensure the float switch
moves freely up and down.
Drain valve is opened during cooking.
Controller is turned on when the SIB board is not configured.
The VIB board fuse has tripped and didn't reset.
The controller has not been programmed with product
recipes.
Replace controller with factory programmed
controller.
Oil temperature is too high for a valid OQS reading. Filter at a
temperature between 300ºF (149ºC) and 375ºF (191ºC).
Oil temperature is too low for a valid OQS reading. Filter at a
temperature between 300ºF (149ºC) and 375ºF (191ºC).
The TPM is too low for a valid OQS reading. This may also be
seen with fresh new oil.
selected in the setup menu. The sensor may not be calibrated
for the oil type. See oil type chart in instruction document
8197316. If issue continues contact an FAS.
The TPM reading is too high for a valid OQS reading. Dispose
the oil.
The OQS has an internal error. If issue continues contact an
FAS.
The OQS is detecting air in the oil. Check the O-rings and
check/tighten prescreen filter to ensure no air is entering the
OQS sensor. If issue continues contact an FAS.
The OQS sensor has a communication error. Check
connections to the OQS sensor. Power cycle the entire fryer
battery. If issue continues contact an FAS.