Fib (Filter Interface Board) Service Procedures; Control Power Reset Switch - Frymaster FilterQuick easyTouch FQG60T Service Manual

Hide thumbs Also See for FilterQuick easyTouch FQG60T:
Table of Contents

Advertisement

1.20 FIB (Filter Interface Board) Service Procedures

The controller has a service mode that allows manually
opening of return and drain valves, manual operation of the
filter pump motor and the ATO pump.
To access the mode, follow these steps:
1.
Press the Home button.
2.
Press the Service button.
3.
Press the Service button again.
4.
Enter 3000 and press the checkmark.
5.
Press Manual Filtration button.
The controller displays the current state of the valves and
pump under the titles (see Figure 44). Pressing the buttons will
perform the action inside the button.
1.20.1 Manually Draining, Refilling, Filtering or Topping Off using the Manual Filtration Mode
Pressing the drain button or the return button activates the drain or return valve for the associated vat. Pressing the
filter pump button or ATO pump button activates the pumps. NOTE: The pumps will not activate unless a return
valve is opened to prevent deadheading of the pumps.
Pressing the home button exits the manual filtration mode. Upon exiting the manual filtration mode, the controller
will prompt to FILL VAT FROM PAN? YES/NO to ensure no oil is left in the filter pan. Follow the prompts to ensure all
oil is returned to the vat.

1.20.2 Control Power Reset Switch

The control power reset switch, is a momentary rocker switch, located in the far-left fryer cabinet (see
Figure 45), that resets all power to all the controllers and boards in the fryer. It is necessary to reset all
power after replacing any controller or board and after any setup change. Press and hold the switch
for at least sixty (60) seconds when resetting the control power to ensure power has sufficiently
drained from boards.
Figure 44
1-37
Figure 45