Frymaster FilterQuick easyTouch FQG60T Service Manual page 18

Hide thumbs Also See for FilterQuick easyTouch FQG60T:
Table of Contents

Advertisement

USB Harness
Locator Wire
5.
With the replacement controller face down resting in the control box, reattach the lanyard tether FIRST. Failure
to reinstall lanyard could result in damage to the SIB board.
6.
Reinstall the controller by reversing steps 1 thru 6.
7.
Setup the controller following the instructions in section 1.7 of the FQ4000 Controller Operation Manual. If the
controller being replaced is in the far-left position the current date and time will need to be setup following the
instruction in section 1.8 of the FQ4000 Controller Operation Manual. Setup MUST be performed prior to reset.
8.
Once setup is complete on all replaced controllers, CYCLE POWER TO ENTIRE FRYER SYSTEM. See section 1.20.2 to
reset control power.
9.
Check software version and if necessary, update the software.
instructions to update the software in section 1.24.
1.15.2 Replacing Control Box Components
(Smart Interface Board (SIB), the Filtration
Interface Board (FIB), Time Delay Relay
Board, KCCM (SUI) communication board, or
the Ignition Module) (NOTE: On some units
the FIB board and KCCM (SUI) board may be
located elsewhere in the fryer.)
1.
Perform steps 1 through 8 from section 1.15.1.
2.
Remove the bezel by removing the two (2) screws on the
bottom of the bezel.
3.
Disconnect the cables attached to the component,
marking or making a note of the connectors to facilitate
reconnection.
4.
Remove the hardware attaching the components.
5.
Remove the component from the box. When removing the boards, be careful not to lose the spacers that fit over
the studs behind the boards.
6.
Reverse the procedure to install the component. Ensure the spacers behind the board are in place and the
controller locator wire is attached to a stud.
7.
Check software version and if necessary, update the software.
instructions to update the software in section 1.24. Press the information (
press the SW version button to verify software version of the FIB. If the FIB software version is not visible,
the FIB may not be connected properly.
RJ-45 Power /
Communication
Figure 2
1-14
If a software update was necessary, follow the
FIB
Figure 3
KCCM (SUI)
Board
If a software update was necessary, follow the
?
) button; press the down arrow;
Lanyard Tether
Speaker
Harness
Ignition
SIB
Module
Time Delay
Relay Board

Hide quick links:

Advertisement

Table of Contents
loading