Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other cooking appliance. WARNING No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline at 1-800-551-8633.
Page 3
It is designed for a tight fit and should only be removed for cleaning. IMPORTANT Safe and satisfactory operation of Frymaster equipment depends upon its proper installation. Installation MUST conform with local codes, or in the absence of local codes, to European Community (CE) Standards.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.1 Functional Description Master Jet (MJ) CF Series Atmospheric gas fryers contain a welded stainless steel frypot that is directly heated by gas flames that are diffused evenly over its lower surface by ceramic targets.
Page 7
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.1 Functional Description (cont.) CONTROL OPTIONS MJCF Series gas fryers may be equipped with thermostat controllers or Computer Magic III.5 computers. KJ3FC variants are equipped with user-supplied or KFC-1 computers.
Page 8
When new, the Fenwal controlling thermostat is sensitive to one-degree changes in temperature. CAUTION Fenwal thermostats are used in a number of Frymaster products. The thermostat for the MJCF Series is 4 inches long. Do not use 3-inch Fenwal thermostats in MJCF Series fryers.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.1 Functional Description (cont.) MJCFE Series fryers equipped with computers have a temperature probe. In these units, the probe resistance varies directly with the temperature. That is, as the temperature rises, so does resistance at a rate of approximately 2 ohms for every 1°...
Page 10
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.3 Checking Burner Manifold Gas Pressure WARNING This task should be performed by qualified service personnel only. 1. Ensure that the gas valve knob or button is in the OFF position.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.3 Checking Burner Manifold Gas Pressure (cont.) Non-CE Standard Non-CE Standard for Incoming Gas Pressures for Burner Manifold Gas Pressures Minimum Maximum Pressure 6" W.C. 14" W.C. 3.5" W.C.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.5 Cleaning Gas Valve Vent Tube 1. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal. 2. Pass a piece of ordinary binding wire (.052 inch diameter) or equivalent through the tube to remove any obstruction.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.7 Calibrating Thermostat Control 1. Fill the frypot to the lower OIL-LEVEL line with oil. If solid shortening is used, it must be tightly packed into the frypot. 2. Light the pilot. (Refer to Installation and Operation Manual that shipped with the fryer for detailed lighting instructions.)
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.7 Calibrating Thermostat Control (cont.) 13. Close the fryer control panel and replace the screws in the upper corners. 14. Reinstall the thermostat knob with its pointer aligned with the 325°F (163°C) index mark on the temperature dial.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.2 Replacing Operating Thermostat CAUTION The thermostat must be calibrated after installation is complete. Refer to Section 1.7 for calibration instructions. When handling the thermostat, do not rotate the shaft more than two turns in either direction.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.3 Replacing Temperature Probe 1. Disconnect the fryer from the electrical supply. 2. Drain the frypot. 3. Remove the screws from the upper left and right corners of the control panel. The panel is hinged at the bottom and will swing open from the top.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.4 Replacing High-Limit Thermostat – Operating Thermostat Controls (cont.) 6. Unscrew the high-limit thermostat from the frypot and remove. 7. Apply Loctite PST567 thread sealant or equivalent to the replacement thermostat threads.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.6 Replacing Heat Mode Indicator Light – Operating Thermostat Controls 1. Disconnect the fryer from the electrical supply. 2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws from the upper left and right corners of the control panel.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.8 Replacing Melt Cycle Timer – Operating Thermostat Controls The mechanical melt cycle timer is no longer available. A solid-state timer replaces the mechanical unit. To replace the mechanical melt-cycle timer: 1.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.9 Replacing Burner Ceramic Targets DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from electrical and gas supplies. 2. On FMCF fryers, remove square-drain sections as necessary to expose burner.
Page 21
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.9 Replacing Burner Ceramic Targets (cont.) 10. To replace only the ceramic targets, straighten the target locking tabs with a pair of needle nose pliers or a screwdriver, and slide the target up and off the bracket. Slide the replacement target onto the bracket and bend the locking tabs inward towards the burner target.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.10 Replacing Gas Valve DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect fryer from electrical and gas supplies 2. Disconnect the wires from the gas valve terminal block, marking each wire to facilitate reconnections.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.11 Replacing Pilot Assembly or Thermopile (cont.) 3. To replace the complete pilot assembly: a. Disconnect the pilot tubing from the bottom of the pilot assembly. b. Remove the screw from the pilot mounting-bracket to release the pilot assembly.
Page 24
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.8.12 Replacing Frypot (cont.) 13. Remove the cover from the safety drain switch, disconnect the wires from the switch, and pull them out of the switch box. 14. Pull up and forward on the component shield to clear the rear mounting stud on the front of the frypot and remove it from the fryer by rotating its right side up and to the left.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9 Troubleshooting and Problem Isolation Because it is not feasible to attempt to include in this manual every conceivable problem or trouble condition that might be encountered, this section is intended to provide technicians with a general knowledge of the broad problem categories associated with this equipment, and the probable causes of each.
Page 26
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.1 Pilot/Ignition Failures (cont.) Ignition failures occur when the 24VAC power supply to the gas valve is interrupted, when the gas supply is interrupted, or when the pilot flame is extinguished.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.2 Improper Burner Functioning The burner ignites but exhibits abnormal characteristics such as "popping", incomplete lighting of the burner, fluctuating flame intensity, and flames "rolling" out of the fryer.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.2 Improper Burner Functioning (cont.) Fluctuating flame intensity is normally caused by either improper or fluctuating incoming gas pressure, but may also be the result of variations in the kitchen atmosphere. Verify incoming gas pressure in the same way as for "popping", discussed in the preceding paragraphs.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.3 Improper Temperature Control (cont.) MELT CYCLE PROBLEMS NOTE: In early 1999, PC board melt cycle timers replaced melt-cycle timer motors in new fryers. See Section 1.8.8 for retrofit information.
Page 30
4. Computer times down too slowly or too quickly. Cause: Computer is compensating for oil temperature via the sensitivity setting. Corrective Action: Reprogram sensitivity setting for each product in accordance with programming instructions in the Frymaster Fryer Controllers User’s Manual that shipped with the computer. 1-25...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.5 Filtration Problems The majority of filtration problems arise from operator error. One of the most common errors is placing the filter paper on the bottom of the filter pan rather than over the filter screen.
Page 32
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.5 Filtration Problems (cont.) Incorrectly sized or installed paper will also allow food particles and sediment to pass through and clog the suction tube on the bottom of the filter carriage. Particles large enough to block the suction tube may indicate that the crumb tray is not installed in the pan during filtering.
Page 33
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.9.6 Leakage Leakage of the frypot is mostly due to improperly sealed high-limits, thermostats/temperature probes, and drain fittings. When installed or replaced, each of these components must be sealed with Loctite PST567 sealant or equivalent to prevent leakage.
Page 34
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES High-limit Pilot Thermostat Generator High-Limit Operating Thermostat Thermostat Safety Drain Switch Pilot Generator In Line Splice HONEYWELL 1/2 PSI ON/OFF Switch (Optional) In Line Splice FENWALL Operating Thermostat Optional ON-OFF switch...
Page 35
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES ROBERTSHAW-UNITROL 7000 SYSTEM CHECK 1. Complete System Check With thermostat contacts closed and gas cock dial in the “ON” position, the main burner should ignite. Measure the reading between the 2 &...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.10 Troubleshooting Guides The troubleshooting guides found in the pages that follow are intended to assist service technicians in quickly isolating the probable causes of equipment malfunctions by following a logical, step-by- step process.
Page 37
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.10.1 Initial Troubleshooting, Millivolt Frying Systems (cont.) PROBLEM PROBABLE CAUSES CORRECTIVE ACTION A. Inadequate make-up air in cooking A. Adjust ventilation system to increase area. make-up air. B. Pilot flame directed away from first B.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.10.2 Initial Troubleshooting, 24VAC Frying Systems PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Burner won’t ignite. A. ON/OFF switch is off. A. Turn ON/OFF switch on. Light in ON/OFF switch is not illuminated.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.10.2 Initial Troubleshooting, 24VAC Frying Systems (cont.) PROBLEM PROBABLE CAUSE CORRECTIVE ACTION A. Incoming gas supply pressures are A. Inspect gas supply to fryer. Repair not within range [Natural- 6-14" W.C.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.12.5 Filter Magic II Wiring Diagram REPEAT SAME CIRCUIT ON NEXT FRYER IF NEEDED SEE INSET A-A FOR 50-2 FILTER PUMP MOTOR ON/OFF SWITCH 1 ST. FRYER - RIGHT OF FILTER...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.1 Accessories...
Page 46
* Not illustrated. Use standard part. In Fall 2004 Frymaster introduced the Euro-Look fryer. The MJCF took on this look in 2006. This fryer has a rounded topcap instead of the traditional 90º angle topcap. Also round drains replaced square drains.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.2 Burner Manifold Components STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 806-0225SP Deflector Assembly (Ceramic Target Assembly), Side 806-3605SP Deflector Assembly (Ceramic Target Assembly), Back...
Page 48
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.2 Burner Manifold Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. Pilot Assembly 810-2071 Natural Gas, w/Thermopile (use 810-0426 for pilot only)
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.3 Cabinetry Components 2.3.1 Fryer Cabinetry STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 201-0486SP 201-6964 Side, Left- FMCF Unitary Cabinet- CRS 211-0486SP...
Page 50
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.3.1 Fryer Cabinetry (cont.) MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # 900-7367SP 201-6916 Side, Left & Right - MJCF CRS Cabinet (Euro Left Side Only)
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.3.2 Filter Magic II & Spreader Cabinet Cabinetry...
Page 52
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.3.2 Filter Magic & Spreader Cabinet Cabinetry (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 201-0486SP 201-6964 Side, Left- Filter Magic/Spreader Cabinet- CRS...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.4 Casters, Legs and Associated Hardware MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # 810-0356 Caster, Swivel, 5", w/o Brake 810-0357 Caster, Swivel, 5", w/Brake 810-0378 Caster, Rigid, 5", w/o Brake...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.5 Component Shield, Filter Box Assemblies and Components 2.5.1 Component Shield Assemblies – No Interface Board Timer and Bracket Assembly is omitted on 806-4774SP and 806-4776SP Component Shield Assemblies without Interface Boards...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.5.1 Component Shield Assemblies – No Interface Board (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. Kit, Melt Cycle Timer (Replaces for Melt Cycle Timer Motor) [Items 5, 6...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.5.2 Component Shield Assemblies – With Interface Board (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. Complete Shield Assemblies 806-4773SP 120V, 50/60 Hz, With Interface Board...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.5.3 Filter Box Assemblies (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 823-1584 Box, Control- FMCF Filter 823-1585 Box, Control- Under-Counter CF-Filter...
Page 58
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.6 Control Panel Assemblies and Related Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 806-4992SP 106-4055 Frame Assembly, Control Panel 809-0448...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.6 Control Panel Assemblies and Related Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 806-2071 Harness, Computer (Computer To Interface Board)
Page 60
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.1.1 Filter Magic Drain Manifold Components (cont.) STANDARD MJCF Euro Look: ITEM COMPONENT PART # ** May 2006 forward. 900-0757 Cover, Drain End, Square Drain- FMCF 816-0032 Gasket, Flange, Square Drain- FMCF 823-0717 Tube, Square Drain- 2-½...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.1.2 Euro-Look Drain Manifold Components See page 2-27 for Euro-Look Drain Valve Assemblies. EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # ** May 2006 forward. 823-4764 Drain Tube, Left End Open /Right End Closed, Short...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.2 Filter Magic II Filter Pan Components – Outer Pan Components CONTACTOR BLOCK ASSEMBLY MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # FMCF Complete Filter Pan Assembly – Inner & Outer Pan 806-6095SP Assembly ( Crumb Screen Not Included –...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.2 Filter Magic II Filter Pan Components – Outer Pan Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 824-0292 Cover, Suction Tube...
Page 64
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.3 Filter Magic Filter Pan Components – Inner Pan Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. FMCF Complete Filter Pan Assembly – Inner & Outer Pan 806-6095SP Assembly ( Crumb Screen Not Included –...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.4 Oil Return Handle Components – Units Built Prior To April 2001 MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # 807-2103 Microswitch 930-0839...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.5 Oil Return Handle Components –Units Built April 2001 and After MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # 807-2103 Microswitch 200-0821 Bracket, Microswitch...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.6 Oil Return Plumbing FLEX LINE TO NEXT POT (WHERE APPLICABLE) OIL RETURN PLUMBING FILTER MAGIC II (TYPICAL) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward.
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.7 Filter Pump and Motor Components STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 900-7026 Base, Motor- Adjustable 810-0665 Nut, Leveling- Adjustable Motor Base...
Page 69
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.7 Filter Pump and Motor Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART# May 2006 forward. 813-0062 Elbow, ½" 90° NPT BM 813-0022 Nipple, ½" x Close NPT BM 813-0165 Elbow, Street- ½"...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.8.1 Drain Valves and Related Components STANDARD ITEM COMPONENT PART # ** 806-4145 Valve, Drain- 1-¼" (Includes Handle With Lock Pin) For non-filter fryers 810-1017 Valve, Drain- 1-¼" (Without Handle)
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.8.2 Euro-Look Drain Valves and Related Components-Round Drains EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # ** May 2006 forward. 106-3760 Valve, Drain Assembly Full Vat 200-6496 Support, Drain 3” Tube...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.7.9 Power Shower Components STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 806-4529SP Power Shower Assembly, Full Vat, Complete 809-0415 Screw, Cleanout 814-0001...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.8 Frypot, High-Limit and Probe Components STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 823-3893SP Frypot, Bare- FMCF & MJCF 106-2553SP Frypot, Complete (Include Combustion Chamber & Insulation)
Page 74
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: PARTS LIST 2.8 Frypot, High-Limit and Probe Components (cont.) STANDARD EURO-LOOK MJCF Euro Look: ITEM COMPONENT PART # PART # May 2006 forward. 813-0408 Plug, Frypot – ¼" NPT BM 813-0156 Plug, Frypot –...
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A.2 Parts List – KJ3FC Variant Parts specific to KJ3FC variants are listed here. All other parts can be found in Chapter 2.
Page 83
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A.2 KJ3FC Variant – Parts List (cont.) MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # 900-4340 Shield, Component 900-1739 Brace, Component Shield 900-1635 Bracket, Component Shield 807-0276 Block, Terminal –...
Page 84
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS APPENDIX A.2 KJ3FC Variant – Parts List (cont.) MJCF Euro Look: STANDARD EURO-LOOK ITEM COMPONENT May 2006 forward. PART # PART # 806-9325 Bracket, Support – Microswitch 809-0126 ¼-20 x 3/8" Slotted Head...