5-4. Adjustment Flow Chart After
Cylinder Unit Replacement
1.
After change the Cylinder Unit, please perform the
adjustment and confirmation as following flow
chart.
START Mechanical Adjustment (Section 4)
4-8. Tension Confirmation
4-11. Envelope Waveform Adjustment
4-12. Post Limit Confirmation (PLAY)
4-16. A/C Head Tilt Confirmation
4-17. A/C Head Height Confirmation
4-18. A/C Head Azimuth & X-value Adjustment
4-19. REV Tape path confirmation & Adjustment
4-21. CTL Self-Recording Level Confirmation
4-22.Play Tape Path Limit Confirmation
4-23. Envelope Waveform Confirmation
(REV/REW/FF)
4-24. Envelope Rising Confirmation
4-25. & 4-26. Tape Path Limit Confirmation
(REV/REW/FF)
4-27. Screw Lock Tight (A/C Head, T3 & T4 Post)
4-28. Tape Damage Confirmation
Note: Envelope level Adjustment
Note: PG Shifter Adjustment
4-29. LISTA Adjustment Procedure
4-30. LISTA Connection and Boot-up
4-32. LISTA Sensitivity Adjustment
4-32. LISTA Sensitivity Detection
4-33. Linearity Adjustment &
4-34. Self-REC/PLAY ENV Confirmation
4-35. DV Playback ENV Confirmation
START Electrical Adjustment
REC CURR & REC FREQ Adj.
NOTE:
Envelope
level
procedure are mentioned on Electrical Adjustment
Procedure on Service Manual.
MECH-34
(Long Play Type)
Waving Measurement
EQ Adjustment
END
and
PG
Shifter
adjustment