2. Table of Test Point
<Table of Test Point>
Name
[ Reel Torque Adjustment ]
S-REEL
Reel output Voltage
Adjustment Point
T-REEL
Reel output Voltage
Adjustment Point
GND
[ Tension Arm Adjustment ]
TENSION
TENSION OFFSET
TENTION GAIN
[ Photo Sensor Voltage Adjustment ]
S-REEL
T-REEL
[ Tape Path, A/C Head Adjustment ]
R/P-ENV L13 (ENV A)
R/P-ENV R13 (ENV B)
R/P-ENV L24 (ENV C)
R/P-ENV R24 (ENV D)
R/P-HSW L13 (HSW A)
R/P-HSW R13 (HSW B)
R/P-HSW L24 (HSW C)
R/P-HSW R24 (HSW D)
CUE
LIVE-CTL
FRP
[ PG SHIFTER Adjustment ]
TSR
SPA L13
SPA L24
PG SHIFT
[ LISTA Adjustment ]
ATF ERR L13
ATF ERR L24
TRG
R/P-HSW L13
R/P-HSW R24
ATF GAIN
SERVICE NENU Adjustment Mode>
Adjustment Name
T-Reel Torque Adjustment
S-Reel Torque Adjustment
PG Shifter Adjustment
LISTA Sensitivity Adjustment
LISTA Linearity Adjustment
Sensor Voltage
Adjustment Point
Sensor Voltage
Adjustment Point
• Select the EVF on the Service Menu.
Select the EVR on the Service Menu.
(Refer to following table)
Adj. MODE (and Adjustment VR)
• Select by Service Menu
"T TORQUE"
"S TORQUE"
"PG SHIF 100"
"RP GAIN 100"
"RP LIN 100"
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
HEAD BUFF C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
SERVO C.B.A
(Refer to below table)
ADJUSTMENT MODE
MECH-2
AJ-HDC27VP
: TP301
: VR502
: TP302
: VR501
: TG300
: TP402
: VR402
: VR401
: TP503
: VR503
: TP504
: VR504
: TP400
: TP401
: TP402
: TP403
: TP500
: TP501
: TP502
: TP503
CUE C.B.A
: TP4
: TP901
: TP502
: TP501
: TP102
: TP103
SERVO C.B.A
: TP601
SERVO C.B.A
: TP602
SERVO C.B.A
: TP113
SERVO C.B.A
: TP114
Remarks
When set the adjustment mode condition,
press the select SW at the EJECT mode.
Playback the alignment tape. Then keep
pressing the select SW until the value on the
EVR is updated.
Test point TRG: HSW L13