5-2. Cleaning Arm Unit
Replacement
(Removal)
1. Unscrew the 2 screws (A) and remove the T1
Guide as shown in Figure 5-2.
2. Widen the tip of the cleaner arm, lift up the
cleaning arm unit and remove the spring and
washer.
(Installation)
1. Install the spring and washer.
2. Insert Cleaning Arm Unit temporary to T2 Arm Unit.
Install the spring to between Cleaner Base Plate
and Cleaning Arm Unit, and insert Cleaner Arm
Unit to T2 Arm Unit perfectly.
3. Rotate the cylinder by hand in the pressing the
core of the Cleaner Solenoid, and confirm that the
Cleaner Roller rotate.
4. Install the T1 Guide.
5. After install the T1 Guide, please perform the item

"5-3. T1 Guide Position Adjustment".

Figure 5-2
5-3. T1 Guide Position Adjustment
1. Place the unit to loading condition without the
tape.
2. Observe the clearance (B) between T1 Guide and
T1 post as shown in Figure 5-3, and make sure
that it is within 0.2mm to 0.5mm.
3. If not, loosen the 2 screws (A) and adjust the
position of the T1 Guide moves to direction of
arrow (G ←→ G) so that the clearance (B) is within
the specification. And tighten the 2 screws (A).
MECH-33