Chapter 7
It is safer to disable "proxy(443)" and "Enable Mode II".
Setting up the Hydro-Control VI and support PC for a custom
2.2
server
The Hydro-Control VI remote support server parameter on the Ethernet Comms page (see
Figure 49) should be set to the IP address and port number or domain name of the custom
server. The Support staff should install UltraVNC viewer and set the proxy/repeater address to
the IP address and port number or the domain name of the custom server that the repeater is
installed on.
3 Configure the Hydro-Control to use a static IP address
The Hydro-Control can be configured to use either a Static or Automatic IP address (Figure 49).
To configure a static IP address select 'Use the following IP address' and enter the required
address. The DNS server can also be manually set.
Once configured select 'Save Settings' to update the Hydro-Control.
To revert back to an automatic IP address select 'Obtain an IP address automatically' and save
the settings.
Figure 51 - Repeater Settings
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
Remote Support