Reading and writing recipe parameters
3.3
The recipe values of each recipe can be set at any time except if the recipe is currently in use.
If the recipe is currently in use then commands to change parameters will be applied to the next
mix started.
To read parameters the following format should be used:
#_R_nn_pp
"_" denotes a space, do not use the underscore character in the RS232 string, "nn" denotes
the recipe number and "pp" denotes the parameter to read.
To write a recipe parameter the following format should be used:
#_W_nn_pp_vv
"_" denotes a space, do not use the underscore character in the RS232 string, "nn" denotes
the recipe number, "pp" denotes the parameter to change and "vv" is the value to set it to.
Cement In Error
Water Meter Fault
Leaking Water Valve
No Water Required
Too Much Water Calculated
Pre-wet Target Not Reached
Mix Too Wet Rejected
Mix Too Dry Rejected
Mix Too Wet Accepted
Mix Too Dry Accepted
Water Limit Exceeded
Max Dry Mix Time Reached
Max Wet Mix Time Reached
Mix Aborted
Sensor Fault
Mixer Blades Worn