Commissioning
The Recipe Editor – Page 2
7.3
Pressing the Next button
recipe editor which has the Mix Control, Local Auto-Track, Admix and Temperature Correction
Settings.
Mix Control
Parameter
Pre-wet Water Control Method
Pre-wet Moisture Target
Control Method
Moisture Target
Plus Tolerance
Minus Tolerance
The Pre-wet Control Method changes the method that is used to control the pre-wet water
addition. If the method is set to Preset, then a fixed quantity of water is added defined by the
parameter Pre-wet Water in the Water Addition section on page 1 of the recipe parameters. If
the method is set to Auto, then the water is added in AUTO Mode to reach the target defined
as Pre-wet Moisture Target.
50
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
at the bottom of the screen displays the second page of the
Figure 36: The recipe editor – page 2
Units
None
%
None
%
%
%
Default
Range
Preset
Preset/Auto/Calculation
8
0 – 99.9 %
Preset
Preset/Auto/Calculation
10
0 – 99.9 %
2.75
0 – 99.9 %
2.75
0 – 99.9 %
Chapter 4
Need help?
Do you have a question about the Hydro-Control VI and is the answer not in the manual?