OPERATING PROCEDURES
14. When the sanitizer stops flowing from the door spout,
close the draw valve. Press the WASH and PUMP
keys to stop the operation.
15. Disconnect the pressure line from the pressure
switch. Drain the sanitizer. Reconnect the pressure
line to the pressure switch.
16. Repeat these steps for the second freezing
cylinder.
17. Prepare a sink with an approved sanitizing solution
(examples: Stera-Sheen
water and follow the manufacturer's specifications.
6
18. Take the following parts to the sink and sanitize: mix
tanks, mix tank covers, mix probes, mix storage
covers, and funnels.

Priming

1. Place the mix tank and the cover in the mix cabinet.
2. Insert the prongs of the mix probe inside the mix
tank. Connect the mix probe in the socket receptacle.
6-12
Figure 6-49
®
®
or Kay-5
). Use warm
Figure 6-50
3. Place the free end of the suction line into the mix
tank.
13038wp
4. Install the funnel. Fill the mix tank with fresh mix.
5. Remove the funnel and install the mix storage cover.
Close the mix cabinet door.
15064