14. Align the drive hole in the piston to the ball crank of
the motor reducer. Simultaneously, align the locating
pin on the face plate.
Slide the pump collar upward into the grooves on the
side of the face plate and secure the air/mix pump in
place by slipping the keeper pin through the 
crossholes of the pump collar.
Important! Alignment of the air/mix pump is
extremely important. Severe and costly damage may
occur when it is not properly aligned.
Figure 6-35
15. Lubricate both sides of the pressure switch
diaphragm.
Figure 6-36
Operating Procedures
16. Place diaphragm into groove of the pressure switch
15055
17. Screw the cap securely onto the housing.
15056
Note:
Apply the appropriate
Taylor approved food safe lubricant.

Sanitizing

1. Prepare a pail of approved 100 ppm sanitizing
2. Place the pail of sanitizing solution inside the mix
Model 8756
OPERATING PROCEDURES
cap.
Figure 6-37
Figure 6-38
Repeat these steps for other the side of freezer.
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
2 gal. [7.6 L] of Stera-Sheen
follow the manufacturer's specifications.
cabinet.
15057
15058
®
or 
®
). Use warm water and
6-9
6