20
*IMPORTANT*
Module Wiring Harness is in the Cut Out and not being hit by the Rear End Cap.
Rear End Cap Cut Out
Select your preferred torque mode (ships in standard torque). Press the
Step 1 -
device push pad to the desired setting. (We recommend to fully depress
and release 5%, giving the device room for changing door conditions.)
While depressing the push pad, apply power. (i.e. presenting the credential
Step 2 -
to the reader).
Continue to keep the pad depressed, the device will beep 6 times. After the
Step 3 -
beeps have stopped, release the pad and the adjustment is now complete.
If not to your liking repeat the 3 steps.
Beeps
2 Beeps
3 Beeps
4 Beeps
5 Beeps
Retraction or dogging failure
6 Beeps
U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w . c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2
installation instructions
After reinstalling the Rear End Cap and its two screws, double check to make sure the
Make sure to set PTS before finishing installation
Troubleshooting & Diagnostics
Explanation
Over Voltage
Under Voltage
Failed Sensor
PUSH TO SET
SPECIFICATIONS for optional rex:
Single Pole - Double Throw (SPDT)
Rating: 0.5A @24VAC
Configuration: Green - Common (C)
Push Pad down, Wiring Harness within Cut Out
Solution
> 30V unit will shut down. Check voltage & adjust to 24 V.
< 20V unit will shut down. Check voltage & adjust to 24 V.
Verify all 3 sensor wires are installed correctly. Replace sensor if problem
persists by contacting office.
After 1st fail: 5 beeps then immediately attempts to retract again.
After 2nd fail: 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.
To Reset: Depress bar for 5 seconds at any time.
Device is recording it's new position and power mode after the 6th beep.
Blue - Normally Open (NO)
Gray - Normally Closed (NC)
10
MM4 SWITCHES
OFF
1
STANDARD TORQUE
ON
HIGH TORQUE
ON
2
PTS PROGRAMMING ON
OFF
PTS PROGRAMMING OFF
# 2 0 3 7 9 _ L

Advertisement

loading
Need help?

Need help?

Do you have a question about the MLRK1 Series and is the answer not in the manual?

Questions and answers

Related Products for Command access MLRK1 Series

This manual is also suitable for:

Mlrk1-jac 12Mlrk1-kaw17Mlrk1-aht