The Command Access MLRK1 is a field installable motorized latch-retraction kit for:
• MLRK1-TS - Town Steel 1100 series devices
• MLRK1-USCAN - USCAN2100 series devices
• MLRK1-LSDA2 - IDN LSDA 9200 series devices
A.
Kit I n c l u de s
1- Motor Mount w/ MM4S series module
A.
B.
2- 40002 - 8/32 X 1/4" Phillips head screws
C.
1- 50030 - 8' Lead w/ Connector
1- 50944 - MM4S Socket Lead
D.
E.
1- 50864 - Spring compression bracket
U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w . c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2
M L R K 1
INSERT Instructions
D.
B.
C.
E.
T o o l s R e q u i r e d
Cordless Drill
5/16 Nut driver (recommended) or
Flat head screwdriver
#2 Phillips head screwdriver
In sta ll at ion vid eo
# 2 0 4 0 1 _ C

Advertisement

loading

Summary of Contents for Command access MLRK1

  • Page 1 M L R K 1 INSERT Instructions The Command Access MLRK1 is a field installable motorized latch-retraction kit for: • MLRK1-TS - Town Steel 1100 series devices • MLRK1-USCAN - USCAN2100 series devices • MLRK1-LSDA2 - IDN LSDA 9200 series devices...
  • Page 2: Technical Information

    Technical Information SPECIFICATIONS MM4 SWITCHES Standard Torque Mode • Input Voltage: 24VDC +/- 10% Average Latch Retraction Current: 900 mA STANDARD TORQUE • Wire gauge: Minimum 18 gauge Average Holding Current: 215 mA HIGH TORQUE • Direct wire run - no relays or access control pts programming on units in-between power supply &...
  • Page 3: Installation Example

    All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w . c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2...
  • Page 4: Installation Instructions

    Installation Instructions Remove (4) screws on head cover Remove mounting bracket & (2) screws with 5/16” nutdriver. ead cover crewS Slide off housing from baserail assembly. Remove push pad by pulling forward & then upwards. uSH Pad Pull back spring and insert spring compression bracket Once bracket is in place, continue to motor in between metal plate attachment...
  • Page 5 Installation Instructions Grabbing the motor kit with the attaching hooks facing down move it towards the PIN at 90°. Grab onto the bottom pin and begin to bring the back of the motor down. Slide motor bracket underneath baserail into the Continue bringing the motor down until it’s to exsisting groves.
  • Page 6 Installation Instructions Hook up to power & test motor functions before finishing the re-assembly. Replace push pad by placing over activating arms & pushing down (A) then back towards end of device (B) Slide baseplate back into housing being careful of pinching motor/REX wires.
  • Page 7 Installation Instructions Replace back mounting bracket & re-install (2) Replace front mounting bracket. screws with 5/16” nut driver. crewS Replace head cover & re-install (4) screws. Connect to power (1) and push down on bar (2). Finish sliding faceplate onto device. Follow Push to Set instructions directions below, remembering to turn the Programming Switch to the off position when completed.