Installing Aquapure ® And Aqualink ® Rs; Figure 6. Removing The Control/Power Center Mounting Brackets From Shipping Position - Jandy AquaPure Installation And Operation Manual

Electronic salt water chlorinator, water purification system power center and cell kit
Hide thumbs Also See for AquaPure:
Table of Contents

Advertisement

3.3 Installing AquaPure® and AquaLink
NOTE The control/power center should be located at or near the equipment pad.
The control/power center is not to be considered as suitable for use as service equipment. Therefore,
it is required to have the appropriate means of disconnection, circuit isolation, and/or branch circuit
protection installed upstream of the power center.
1. Locate the control/power center at least five (5) feet or more away from pool/spa and five (5) feet off
the ground. All national, state, and local codes are applicable.
NOTE For Canadian installations, the control/power center must be at least three (3) meters (9.8 feet) away from the
pool/spa and 1.5 meters (5 feet) above the ground.
2.
The control/power center comes with two (2) full length, heavy duty mounting brackets fastened to
the back of the power center during shipping. Remove the four (4) screws that are holding the two (2)
brackets and the cardboard shipping cover in place (see Figure 6). Remove and discard the cardboard.
AquaPure Control Center
Figure 6.
Removing the Control/Power Center Mounting Brackets from Shipping Position
3.
Using the top mounting bracket as a guide, mark three (3) holes on the mounting surface where the
power center will ultimately reside (see Figure 7). Drill the holes in the mounting surface.
NOTE The three mounting holes are four inches (4") apart center to center.
NOTE Use heavy-weight screws. The power center with all available components installed can weigh up to 50
pounds.
Mounting Bracket
Figure 7.
Mark Holes using Control/Power Center Mounting Bracket
RS PureLink
®
CAUTION
Remove the four (4)
screws that secure the
brackets to the Power
Center during shipping
Cardboard Shipping Cover
Mounting Brackets (2)
Mark Holes on Mounting Surface
4"
4"
Control/Power Centers
TM
AquaLink RS PureLink
Power Center
Page 15